In some countries a diagnosis of occupational asthma for medicolegal purposes is made when a questionnaire is suggestive and the individual is exposed to a product known to be a sensitizer. The value of an open questionnaire administered by physicians with experience in occupational asthma is unknown, however. We prospectively assessed all subjects (162) referred to our clinic because their physicians thought their asthma might be work related. The medical questionnaire included questions about the nature of the symptoms (dyspnea, wheezing, cough, and chest tightness) and the timing (worse at work or after a shift at work or improved during weekends or holidays). An initial clinical assessment was set by the physician on a scale that ranged from highly probable to probable, uncertain, unlikely, or absent. Subjects then underwent objective assessment with specific inhalation challenges (n = 72), serial monitoring of peak expiratory flow rates for periods at work and away from work (n = 29), or both (n = 61), to confirm or rule out the diagnosis of occupational asthma. A total of 75 subjects (46%) were shown to have occupational asthma. Symptoms alone (type and timing) did not provide a satisfactory differentiation between those subjects with and those without occupational asthma. For example, 66 of 75 (88%) subjects with occupational asthma said that their symptoms improved during holidays, but 66 of 87 (76%) subjects without occupational asthma experienced a similar improvement.(ABSTRACT TRUNCATED AT 250 WORDS)
Serial peak expiratory flow (PEF) assessment has been proposed in the clinical evaluation of asthma. In subjects attending the asthma clinic of a tertiary care hospital, we wanted to assess: 1) compliance in performing PEF; and 2) accuracy of a PEF-diary.Twenty adult asthmatic subjects, all using inhaled steroids, were asked to assess their PEF in the morning and evening with a VMX instrument (Clement Clarke Int., Colombus, OH, USA). This instrument, which incorporates a standard miniWright peak flow meter, stores PEF data on a computer chip. Subjects were not informed that the values were being stored.The mean duration of PEF monitoring was 89 days (range 44-131 days). For the total of 20 subjects, it was estimated that 3,482 values should have been written down and stored on the VMX computer chip. Whilst 1,897 values (54%) were written down, only 1,533 (44%) were stored, 425 values being invented. Morning and evening values were stored on 34% of days; and values were stored at least once a day on 55% of days. The values written down corresponded precisely to stored values 90% of the time, and were within ±20 L 94% of the time.We conclude that: 1) compliance with daily peak expiratory flow assessments is generally poor in chronic stable asthmatic subjects assessed on two visits separated by a 3 month period; and 2) a substantial percentage of values (22%) is invented.The unsatisfactory compliance with peak expiratory flow monitoring in this group of asthmatics on inhaled steroids underlines the need for similar studies on peak expiratory flow monitoring as part of an action treatment plan, and in more severe and brittle asthmatics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.