The Spallation Neutron Source project includes a superconducting linac section in the energy range from 186 MeV to 1000 MeV. For this energy range two types of cavities are needed with geometrical β values of β=0.61 and β=0.81. An aggressive cavity prototyping program is being pursued at Jefferson Lab, which calls for fabricating and testing four β=0.61 cavities and two β=0.81 cavities. Both types consist of six cells made from high purity niobium and feature one HOM coupler of the TESLA type on each beam pipe and a port for a high power coaxial input coupler. Three of the four β=0.61 cavities will be used for a cryomodule test at the end of 2001. Two cavities of each type have been fabricated and the first tests on both cavities exceeded the design values for gradient and Q value: E acc = 10.1 MV/m and Q = 5×10 9 at 2.1K for the β=0.61 and E acc = 12.5 MV/m and Q = 5×10 9 at 2.1 K for the β=0.81.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.