Using passive headspace concentration (ASTM E-1412) and gas chromatographic/mass spectrometric (GC/MS) analysis as described in ASTM E-1618, the authors have studied the volatile components detectable in several kinds of otherwise uncontaminated substrata, including clothing, shoes, household products, building materials, paper products, cardboard, and adhesives. Due to the use of petroleum-derived liquids in the manufacture of these materials, it is frequently possible to detect the liquids, even when the products are several years old. These results point out the need for the use of comparison samples whenever possible.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.