The minimal instrumentation voltammetry with manual staircase voltage scan allows to obtain electrochemical results with non-commercial equipment. Several researches have demonstrated its analytical and metrological validity; however, some variables have not been studied in this kind of methods, such as the effect of the supporting electrolyte on the repeatability of the voltammograms. In this paper, a study is presented about the effect of KNO3, KCl, KClO4, K2SO4 and Na2SO3 as supporting electrolytes on the voltammograms obtained for the oxidation of KI and succinic acid, both at 0,1 mol/L; ascorbic acid 0,01 mol/L and potassium hexacyanoferrate (II) 0,08 mol/L, all of them as an analytical model. A graphite microdisc was used as working electrode; a bar of the same material was used as the auxiliary electrode. A silver electrode was used as the reference electrode. The Analysis of Variance was the statistical tool for the comparison of the voltammetric currents. A Multiple Range Contrast by a Fisher's LSD Test was used to identify the groups with statistical differences. There were statistical differences between the currents obtained with different supporting electrolytes for all the electroactive species studied. The best voltammetric results were obtained using KCl and KNO3 as supporting electrolytes.
O conteúdo deste livro está licenciado sob uma Licença de Atribuição Creative Commons Atribuição-Não-Comercial NãoDerivativos 4.0 Internacional (CC BY-NC-ND 4.0). Direitos para esta edição cedidos à Editora Artemis pelos autores. Permitido o download da obra e o compartilhamento, desde que sejam atribuídos créditos aos autores, e sem a possibilidade de alterá-la de nenhuma forma ou utilizá-la para fins comerciais.A responsabilidade pelo conteúdo dos artigos e seus dados, em sua forma, correção e confiabilidade é exclusiva dos autores. A Editora Artemis, em seu compromisso de manter e aperfeiçoar a qualidade e confiabilidade dos trabalhos que publica, conduz a avaliação cega pelos pares de todos manuscritos publicados, com base em critérios de neutralidade e imparcialidade acadêmica.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.