In the long-term follow-up after CoA repair, a gothic arch shape is associated with a decreased ascending aorta distensibility with an increased loss of systolic wave amplitude across the aortic arch. These findings explain at least in part the association between this abnormal arch geometry and late HT at rest and on exercise, left ventricular hypertrophy, and adverse cardiovascular outcome in this group of young adults with successful repair of CoA.
Left ventricle (LV) systolic dysfunction in repaired tetralogy of Fallot (TOF) has been identified as a risk factor for functional status and adverse outcome. The aims of this cross-sectional followed by a prospective study were: (1) to evaluate the prevalence of LV systolic dysfunction in a large cohort of adults with repaired tetralogy of Fallot, (2) to test the relationship between LV systolic dysfunction and other known risk factors and (3) to evaluate the impact of LV systolic dysfunction on adverse cardiac events. In a multicenter study, 237 adults repaired TOF (58 % males, age 30 ± 10 years) were evaluated by cardiac magnetic resonance (CMR). Demographics, surgical history, ECG, Echo-Color Doppler and follow-up data were recorded. LV was dilated (Z value >2) in 16 patients (6 %), however 56 patients (23.6 %) had a reduced LV systolic function left ventricle ejection fraction (LVEF) (Z value <-2). Patients with LV systolic dysfunction were mainly males (82 %), had reduced right ventricle ejection fraction (RVEF), and higher right and left Late Gadolinium Enhanced scores. In a multivariate regression analysis male gender and RVEF resulted to be independent factors associated to LV systolic dysfunction. Atrial arrhythmias were the main adverse cardiac event at the follow-up and were associated to higher biventricular volumes and lower biventricular ejection fraction (EF); however multivariable analysis identified age, right ventricle end-diastolic volume (RVEDVi) and tricuspid regurgitation as independents factors associated to atrial arrhythmias. At long term follow-up at least ¼ of repaired TOF has LV dysfunction. Lower LVEF is associated to male gender and lower RVEF.
The immune system protects the organism from foreign invaders and foreign substances and is involved in physiological functions that range from tissue repair to neurocognition. However, an excessive or dysregulated immune response can cause immunopathology and disease. A 39-year-old man was affected by severe hepatosplenic schistosomiasis mansoni and by amyotrophic lateral sclerosis. One question that arose was, whether there was a relation between the parasitic and the neurodegenerative disease. IL-17, a proinflammatory cytokine, is produced mainly by T helper-17 CD4 cells, a recently discovered new lineage of effector CD4 T cells. Experimental mouse models of schistosomiasis have shown that IL-17 is a key player in the immunopathology of schistosomiasis. There are also reports that suggest that IL-17 might have an important role in the pathogenesis of amyotrophic lateral sclerosis. It is hypothesized that the factors that might have led to increased IL-17 in the hepatosplenic schistosomiasis mansoni might also have contributed to the development of amyotrophic lateral sclerosis in the described patient. A multitude of environmental factors, including infections, xenobiotic substances, intestinal microbiota, and vitamin D deficiency, that are able to induce a proinflammatory immune response polarization, might favor the development of amyotrophic lateral sclerosis in predisposed individuals.
Late dysfunction of the systemic right ventricle in patients with complete transposition of the great arteries after Mustard or Senning procedures and progressive deterioration of the clinical status has been demonstrated. However, evidence-based data on the effective therapy for systemic right ventricular dysfunction in these patients are yet to be defined. Our patient shows an improvement in the right ventricular systolic function, with a reduction in tricuspid regurgitation and a consequent better exercise tolerance after a hybrid approach consisting of an upgrading of a previous transvenous-implanted dual-chamber Implantable Cardiac Defibrillator to biventricular pacing associated with pulmonary artery banding via an anterior thoracotomy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.