Excessive urination can be a perioperative challenge for providers due to the possibility of secondary hypernatremia. Dexmedetomidine has previously been reported by several groups to induce a polyuric-like syndrome; however, the exact mechanism in humans remains unclear. In this report, we discuss a case of intraoperative, transient dexmedetomidine bolus-induced excessive urination and suggest a potential mechanism by which this may occur in a subset of the population.
Quadricuspid aortic valve (QAV) is a rare congenital anomaly often associated with aortic insufficiency. The exact anatomy of QAV is variable, and most cases have undergone aortic valve replacement. With the recognition that aortic valve repair achieves superior patient outcomes as compared to replacement, a systematic approach to autologous reconstruction of QAV is needed. This article reports 2 cases having successful repair utilizing geometric aortic annuloplasty rings, and describes a proposed scheme for repairing most QAV defects, based on relative leaflet and commissural characteristics. Using either tri-leaflet or bicuspid ring annuloplasty, the normal sub-commissural triangles can be remodeled into a 120° or 180° configuration, respectively, and then the leaflets can be sutured and plicated to fit annular geometry. With this approach, most quadricuspid valves potentially could undergo autologous reconstruction.
Intraoperative defibrillation secondary to the usage of electrocautery in a patient with a cardiovascular implantable electronic device is a rare occurrence, and below-the-umbilicus electrocautery use causing inadvertent defibrillation is a near-zero risk. Defibrillation secondary to electrodispersive pad (EDP) radiofrequency dispersion has only ever been theorized. In this report, we describe the case of a 67-year-old male with an automatic implantable cardioverter defibrillator (AICD) undergoing a robotic-assisted left anterior total hip arthroplasty for left hip osteoarthritis who experienced inadvertent intraoperative defibrillation concurrent with electrocautery usage. The defibrillations ceased following contralateral EDP repositioning and application of a donut magnet overlying the patient's AICD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.