The proximal and distal metaphyseal areas of the tibia have a rich extraosseous blood supply provided primarily by branches of the ATA and the PTA. Open plating of the medial aspect of the distal tibia caused a greater disruption of this extraosseous blood supply than did percutaneously applied plates. Disruption of these extraosseous vessels following fracture and subsequent operative stabilization may slow healing and increase the risk of delayed union and nonunion. These findings support current efforts to develop less invasive methods and implants for operative stabilization of distal tibia fractures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.