The adoption of dense wireless sensor networks in industrial plants is mandatorily paired with the development of methods and tools for connectivity prediction. These are needed to certify the quality (or reliability) of the network information flow in industrial scenarios which are typically characterized by harsh propagation conditions. Connectivity prediction must account for the possible coexistence of heterogeneous radio-access technologies, as part of the Industrial Internet of Things (IIoT) paradigm, and easily allow postlayout validation steps. The goal of this paper is to provide a practical evaluation of relevant coexistence problems that may occur between industrial networks employing standards such as WirelessHART IEC 62591, IEEE 802.15.4, and IEEE 802.11. A number of coexistence scenarios are experimentally tested using different radio platforms. For each case, experimental results are analyzed to assess tolerable interference levels and sensitivity thresholds for different configurations of channel overlapping. Finally, the problem of over-the-air spectrum sensing is investigated in real scenarios with heterogeneous industrial networks to enable a cognitive resource allocation that avoids intolerable interference conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.