This paper aims to evaluate the dosimetric characteristics of modified VIPARnd for radiotherapy dosimetry using optical investigations. The absorbance spectrum of the irradiated gel dosimeter was evaluated optically with spectrophotometer techniques and with a CMOS imaging system. The useful dose range for the peak value and the relative area under the absorbance curve is 3-20 Gy. The dose-response curve for CMOS readout has an interval of linearity from 3-20 Gy. The modified VIPARnd developed has a good dose range and good temporal stability in the spectrophotometric analysis of the intervals studied. The CMOS readout is transportable, cheaper, easier to use and an excellent alternative for dosimetry.
Purpose The aim of this work was to evaluate the SunCHECK PerFRACTION, the software for in vivo monitoring using EPID images. Materials/Methods First, the PerFRACTION ability to detect errors was investigated simulating two situations: (1) variation of LINAC output and (2) variation of the phantom thickness. An ionization chamber was used as reference to measure the introduced dose variations. Both tests used EPID in integrated mode (absolute dose). Second, EPID measurements in integrated mode were carried out during an independent Brazilian governmental audit that provided four phantoms and TLDs. PerFRACTION calculated the absolute dose on EPID plane, and it compared with predicted calculated dose for every delivered plan. The dose deviations reported using PerFRACTION were compared with dose deviations reported by the independent audit. Third, an end‐to‐end test using a heterogeneous phantom was performed. A VMAT plan with EPID in cine mode was delivered. PerFRACTION calculated the mean dose on CBCT using EPID information and log files. The calculated doses at four different points were compared with ionization chambers measurements. Results About the first test, the largest difference found was 1.2%. Considering the audit results, the variations detected by TLD measurements and by PerFRACTION dose calculation on EPID plane were close: 12 points had variations less than 2%, 2 points with variation between 2% and 3%, and 2 points with deviations greater than 3% (max 3.7%). The end‐to‐end tests using a heterogeneous phantom achieved dose deviation less than 1.0% in the water‐equivalent region. In the mimicking lung region, the deviations were higher (max 7.3%), but in accordance with what is expected for complex situations. Conclusion The tests results indicate that PerFRACTION dose calculations in different situations have good agreement with standard measurements. Action levels were suggested for absolute dose on EPID plane as well as 3D dose calculation on CBCT using PerFRACTION.
Agradeço a Deus por mais essa conquista. Aos meus pais, Valter e Maria Inês, por estarem sempre presentes, por acreditarem em mim, pelo amor, paciência, cuidados e incentivo. Ao meu esposo Thyago Fressatti Mangueira, companheiro e amigo, meu maior incentivador, por seu amor, apoio e compreensão. Agradeço também pela parceria durante todas as etapas deste trabalho e pela grande colaboração cientifica sobre a dosimetria gel. À toda a minha família pela compreensão e apoio, em especial aos meus tios Antônio Sérgio e Ana e aos meus primos Bruno, Elizabete, Júlio e Flávio. Aos meus queridos amigos que estiveram presentes, em especial à Gisele, Simone e Adriana pela grande amizade e apoio. Aos colegas de trabalho pela compreensão, em especial a Beatriz pelo incentivo e ombro amigo nas horas árduas. À minha orientadora, Artemis Marti Ceschin pela paciência, pela confiança, credibilidade, dedicação e trabalho ao longo do meu mestrado. À minha co-orientadora, Roseany de Vasconcelos Vieira Lopes, pelos ensinamentos, paciência, amizade, e pela ajuda no desenvolvimento deste trabalho.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.