A simple reversed-phase HPLC method was developed for routine analysis of lactic acid in Ciprofloxacin Injection. The analysis involves simple sample preparation to ensure complete hydrolysis of the oligomers of lactic acid. Using these conditions, recoveries ranging from 97.5 to 99.9% at three levels of the label claim were obtained. The standard solution and the sample solution were shown to be stable for at least 41 hours when stored at room temperature. Tests done have also demonstrated that the method is stable despite small changes in experimental conditions. Data supporting the development and validation of this method are presented.
Recent studies in our laboratories have focused on the reliability of direct-reading instruments for the determination of airborne isocyanate concentrations. The evaluation of airborne isocyanates is complicated because these substances exist as diisocyanate monomers and polyisocyanate oligomers, both in the vapor and aerosol phases. The studies showed that a number of direct-reading instruments, including the SureSpot test kit, do not allow an accurate determination of isocyanates in the aerosol phase. Using a test chamber, concentrations of various commercial polymeric methylenediphenyl diisocyanates (PMDI) were generated in the aerosol phase to examine the correlation between the SureSpot monitor and two laboratory methods. The results obtained with the SureSpot and laboratory methods correlated poorly. More precisely, the results indicated that the SureSpot direct-reading instrument had a distinctive response to each commercial PMDI and, in addition, it was not accurate for the determination of total PMDI in the aerosol phase. It seemed that the analytical response of the SureSpot is based on a calibration curve only reliable for MDI and not for the determination of PMDIs in the aerosol phase. Further investigation also indicated that the calibration provided by the manufacturer could not be converted into a linear curve over the suggested MDI concentrations range. An appropriate calibration procedure was developed in our laboratories for the SureSpot to accurately determine all commercial PMDIs without great variability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.