Ambient particulate matter (PM) pollution is a major environmental health risk in urban areas. Dense networks of low-cost air quality sensors are emerging to characterize the spatially heterogeneous concentrations that are typical of urban settings, but are not adequately captured using traditional regulatory monitors at central sites. In this study, we present the 100×100 BC Network, a 100-day deployment of low-cost black carbon (BC) sensors across 100 locations in West Oakland, California. This 15 km2 community is surrounded by freeways and affected by emissions associated with local port and industrial activities. We assess the reliability of the sensor hardware and data collection systems, and identify modes of failure to both quantify and qualify network performance. We illustrate how dynamic, local emission sources build upon background BC concentrations. BC concentrations varied sharply over short distances (∼100 m) and timespans (∼1 hour), depending on surrounding land use, traffic patterns, and downwind distance from pollution sources. Strong BC concentration fluctuations were periodically observed over the diurnal and weekly cycles, reflecting the impact of localized traffic emissions and industrial facilities in the neighborhood. Overall, the results demonstrate how distributed sensor networks can reveal the complex spatiotemporal dynamics of combustion-related air pollution within urban neighborhoods.
Urban concentrations of black carbon (BC) and other primary pollutants vary on small spatial scales (<100m). Mobile air pollution measurements can provide information on fine-scale spatial variation, thereby informing exposure assessment and mitigation efforts. However, the temporal sparsity of these measurements presents a challenge for estimating representative long-term concentrations. We evaluate the capabilities of mobile monitoring in the represention of time-stable spatial patterns by comparing against a large set of continuous fixed-site measurements from a sampling campaign in West Oakland, California. Custom-built, low-cost aerosol black carbon detectors (ABCDs) provided 100 days of continuous measurements at 97 near-road and 3 background fixed sites during summer 2017; two concurrently operated mobile laboratories collected over 300 h of in-motion measurements using a photoacoustic extinctiometer. The spatial coverage from mobile monitoring reveals patterns missed by the fixed-site network. Time-integrated measurements from mobile lab visits to fixed-site monitors reveal modest correlation (spatial R 2 = 0.51) with medians of full daytime fixed-site measurements. Aggregation of mobile monitoring data in space and time can mitigate high levels of uncertainty associated with measurements at precise locations or points in time. However, concentrations estimated by mobile monitoring show a loss of spatial fidelity at spatial aggregations greater than 100 m.
Low-cost air pollution sensors are emerging and increasingly being deployed in densely distributed wireless networks that provide more spatial resolution than is typical in traditional monitoring of ambient air quality. However, a low-cost option to measure black carbon (BC)—a major component of particulate matter pollution associated with adverse human health risks—is missing. This paper presents a new BC sensor designed to fill this gap, the Aerosol Black Carbon Detector (ABCD), which incorporates a compact weatherproof enclosure, solar-powered rechargeable battery, and cellular communication to enable long-term, remote operation. This paper also demonstrates a data processing methodology that reduces the ABCD’s sensitivity to ambient temperature fluctuations, and therefore improves measurement performance in unconditioned operating environments (e.g., outdoors). A fleet of over 100 ABCDs was operated outdoors in collocation with a commercial BC instrument (Magee Scientific, Model AE33) housed inside a regulatory air quality monitoring station. The measurement performance of the 105 ABCDs is comparable to the AE33. The fleet-average precision and accuracy, expressed in terms of mean absolute percentage error, are 9.2 ± 0.8% (relative to the fleet average data) and 24.6 ± 0.9% (relative to the AE33 data), respectively (fleet-average ± 90% confidence interval).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.