An ultra-high performance liquid chromatography method for simultaneous determination of tacrolimus impurities in pharmaceutical dosage forms has been developed. Appropriate chromatographic separation was achieved on a BEH C18 column using gradient elution with a total run time of 14 min. The method was applied to analyses of commercial samples and was validated in terms of linearity, precision, accuracy, sensitivity and specificity. It was found to be linear, precise and accurate in the range of 0.05 to 0.6 % of the impurities level in pharmaceutical dosage forms. Stability indicating power of the method was demonstrated by the results of forced degradation studies. The forced degradation study in solution revealed tacrolimus instability under stress alkaline, thermal, light and photolytic conditions and in the presence of a radical initiator or metal ions. The drug was stable at pH 3–5. Solid-state degradation studies conducted on amorphous tacrolimus demonstrated its sensitivity to light, elevated temperature, humidity and oxidation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.