The arthroscopic extraarticular Bankart procedure tries to imitate the open Bankart procedure. An anterior-inferior transmuscular approach through the subscapular muscle permits to implant self-locking tacks into the anterior inferior third of the glenoid rim. The extraarticular location of the implants makes a superomedial capsular shift possible, if required. A total of 257 arthroscopic repairs following traumatic recurrent anterior shoulder dislocation have been carried out between 1992 and 1996. 177 patients were treated only with bioabsorbable Suretac device. Clinical and radiological follow up was possible in 165 patients. According to the Rowe score 69.7% were classified as excellent, 10.9% as good, 9.7% fair and 9.7% poor. Postoperative complications: the recurrence rate was 9.7%, allergic reactions representing a foreign body reaction to the synthetic material were seen in 5 cases (3%) and a frozen shoulder in 6 cases 3.6%). 61% of the patients involved in overhead or contact sports returned to their preoperative sport activities.
Patients sustaining cervical spine trauma have a small but real chance of injuring their face as well. The cervical spine must be examined carefully, whenever facial injuries are present.
The arthroscopic extraarticular Bankart procedure tries to imitate the open Bankart procedure. An anterior-inferior transmuscular approach through the subscapular muscle permits to implant self-locking tacks into the anterior inferior third of the glenoid rim. The extraarticular location of the implants makes a superomedial capsular shift possible, if required. A total of 257 arthroscopic repairs following traumatic recurrent anterior shoulder dislocation have been carried out between 1992 and 1996. 177 patients were treated only with bioabsorbable Suretac device. Clinical and radiological follow up was possible in 165 patients. According to the Rowe score 69,7 % were classified as excellent, 10,9 % as good, 9,7 % fair and 9,7 % poor. Postoperative complications: the recurrence rate was 9,7 %, allergic reactions representing a foreign body reaction to the synthetic material were seen in 5 cases (3 %) and a frozen shoulder in 6 cases 3,6 %). 61 % of the patients involved in overhead or contact sports returned to their preoperative sport activities.
We report outside protrusion of resorbable Biofix arrows after repair of a medial meniscus tear in a 10-year-old boy. One arrow protruded spontaneously. At surgery the other partially resorbed arrow was found subcutaneously. The tear of the medial meniscus had healed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.