A gas chromatography-mass spectrometry (GC-MS) method was developed for the analysis of 15 polycyclic aromatic hydrocarbons (PAHs) highlighted as carcinogenic by the Scientific Committee on Food (SCF) plus benzo[c]fluorine (recommended to be analysed by the Joint FAO/WHO Expert Committee on Food Additives (JECFA) in fat-containing foods such as edible oils and smoked meat products. This method includes accelerated solvent extraction (ASE) and the highly automated clean-up steps gel permeation chromatography (GPC) and solid-phase extraction (SPE). Using a VF-17ms GC column, a good separation of benzo[b]fluoranthene, benzo[j]fluoranthene and benzo[k]fluoranthene was achieved. Futhermore, the six methylchrysene isomers and the PAH compounds with a molecular weight of 302 Daltons in fat-containing foods attained a better chromatographic separation in comparison with a 5-ms column. The reliability of the analytical method for edible oils was demonstrated by the results from a proficiency test. Measurements with GC-high-resolution mass spectroscopy (HRMS) and gas chromatography-mass selective detection (GC-MSD) led to comparable results. A survey of the 16 PAHs in 22 smoked meat products showed concentrations in the range < 0.01-19 microg kg(-1). The median concentration for benzo[a]pyrene was below 0.15 microg kg(-1).
For the analysis of the 15 polycyclic aromatic hydrocarbons (PAH) classified as priority from the Scientific Committee on Food (SCF) and benzo[c]fluorene (BcL) assessed to be relevant by the Joint FAO/WHO Experts Committee on Food Additives (JECFA) in food, a sensitive analytical method is necessary. In the past, many methods were established for only the analysis of the 16 priority PAH recommended by the US Environmental Protection Agency (16 EPA-PAH) but not for the 15 SCF-PAH and BcL. Therefore, at the Max-Rubner-Institut, Federal Research Institute of Nutrition and Food in Kulmbach, Germany, an analytical method with a runtime of 72 min was developed. To shorten this runtime without a loss of separation, a Fast-GC/high resolution MS (HRMS) method with a runtime of only 25 min using a TR-50ms column (10 m x 0.1 mm x 0.1 microm) was created. The repeatability (n = 3) of spiked PAH concentrations in test-matrix tea ranged from 0.1 to 11%. The analytical parameters LOD (0.01-0.02 microg/kg) and LOQ (0.03-0.06 microg/kg) also in the test-matrix tea were determined. A good linearity for all PAH (R(2) >0.99) and averaged recoveries from 75 to 117% in the concentration range of 1-20 microg/kg were achieved.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.