Although patients improved over the 2-year follow-up regardless of initial treatment, those undergoing decompressive surgery reported greater improvement regarding leg pain, back pain, and overall disability. The relative benefit of initial surgical treatment diminished over time, but outcomes of surgery remained favorable at 2 years. Longer follow-up is needed to determine if these differences persist.
The accuracy of pedicle screw placement using computer-assisted surgery proved to be superior to the accuracy obtained when using conventional techniques.
The aim of this study was to describe the contrast-enhanced magnetic resonance imaging (MRI) appearance of bone tunnel enlargement detected on radiography after anterior cruciate ligament (ACL) reconstruction with semitendinosus and gracilis tendon endobutton (STG-endobutton) fixation technique. Fourteen patients with a STG-endobutton ACL reconstruction were examined 3 months (n = 1), 1 year (n = 1) and 2 years (n = 12) postoperatively. An age- and sex-matched group with a bone-patellar tendon-bone (BTB) autograft ACL reconstruction with similar follow-up was taken as control. Data on clinical examination, laxity and isokinetic muscle torque measurements, anteroposterior and lateral view radiography were obtained, and knee scores (Lysholm and Tegner) were collected. Contrast-enhanced MRI was performed in the STG-endobutton group with a 1.5-T imager. There were no statistical differences between the groups with respect to clinical findings, stability tests, or knee scores. In the STG-endobutton group the average femoral and tibial bone tunnel diameter detected on anteroposterior view radiography had increased at 2-year follow-up by 33% and 23%, respectively. On MRI the ligamentous graft itself was not enhanced by the contrast medium whereas periligamentous tissue within and around the STG graft bundles showed mild contrast enhancement. In conclusion, the MRI results suggest that enhancing periligamentous tissue accumulated in and around the STG graft associated with the tunnel expansion. In spite of the significant bone tunnel enlargement observed on the follow-up radiography the STG-endobutton knees were stable and the patients satisfied.
A prospective study of the accuracy of titanium pedicle screw placement in 30 low back operations was performed. The postoperative plain radiographs and CT reformation images were evaluated by two independent radiologists. Thirty-two out of 152 screws (21%) perforated the pedicle cortex. One-tenth of the perforations was detected with conventional radiography. In ten patients (33%) all the screws were located within the pedicle. The clinical significance of this study lies in the finding that pedicle perforations are more frequent than is generally believed and that, in spite of the many malplacements, no screw that perforated by less than 4.0 m m caused neurological problems. Only one nerve root lesion was detected.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.