Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website.Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre -including this research content -immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. CorrespondenceKeratoconjunctivitis as the initial medical presentation of the novel coronavirus disease 2019
Results-There were 18 eyes in each group. Baseline characteristics were similar in both groups. In the SLT group the mean IOP at baseline, 1, 3, and 6 months was 22.8 (SD 3.0), 20.1 (4.6), 19.3 (6.0), and 17.8 (4.8) mm Hg, respectively. In the ALT group, the mean IOP at baseline, 1, 3, and 6 months was 22.5 (3.6), 19.5 (4.7), 19.6 (5.6), and 17.7 (3.3) mm Hg, respectively. There was a greater anterior chamber reaction, 1 hour after SLT v ALT (p< 0.01). Patients with previous failed ALT had a better reduction in IOP with SLT than with repeat ALT (6.8 (2.4) v 3.6 (1.8) mm Hg; p = 0.01).Conclusion-SLT appears to be equivalent to ALT in lowering IOP during the first 6 months after treatment. There is a slightly greater anterior chamber reaction 1 hour after SLT. Patients with previous failed ALT had a significantly greater drop in IOP when treated with SLT v ALT. These results need to be confirmed with a larger sample size. (Br J Ophthalmol 1999;83:718-722) Argon laser trabeculoplasty (ALT) has become the standard method of treatment for medically uncontrolled open angle glaucoma in North America.1 2 It has been in use since 1979 when it was first described by Wise and Witter. 3 Argon laser ( = 488-514 nm) improves the outflow of aqueous by photocoagulation of the trabecular meshwork (TM). A number of theories have been proposed to explain this eVect of ALT on aqueous outflow. The most widely accepted are the mechanical and cellular theories. According to the mechanical theory, ALT causes coagulative damage to the trabecular meshwork, which results in collagen shrinkage and subsequent scarring of the TM. This tightens the meshwork in the area of each burn and reopens the adjacent, untreated intertrabecular spaces.2-4 The cellular theory proposes that in response to coagulative necrosis induced by the laser, there is migration of macrophages, which phagocytose debris and thus clear the TM. DiVerent types of lasers with various wavelengths are being investigated for laser trabeculoplasty. Recently, a Q switched, frequency doubled Nd:YAG laser ( = 532 nm) has been described for use in trabeculoplasty 5-7 (Mark A Latina, presented at AAO Annual Meeting, San Francisco, 1997). In tissue cultures, it has been demonstrated that the low power and short duration of this laser can selectively target pigmented TM cells while sparing adjacent cells and tissues from collateral thermal damage and can thus maintain the architecture of the TM.8 This procedure has thus been termed selective laser trabeculoplasty (SLT).The objective of our study was to compare the eYcacy of SLT and ALT in lowering the intraocular pressure (IOP) in patients with open angle glaucoma in a prospective randomised clinical trial. Patients and methodsA prospective randomised clinical trial was approved by the research ethics board of Ottawa Hospital. The patients included in this trial were those referred to the glaucoma clinic at the University of Ottawa Eye Institute. Patients were included if they had open angle glaucoma (to increase the generali...
Ab interno trabeculectomy using this new incisional procedure safely lowered IOP to the mid teens, with an overall greater reduction in exfoliation glaucoma and improved success when combined with cataract surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.