This paper reviews the causes of barodontalgia and reports on a study that indicates a possible cause of barodontalgia in the diver. In the study, extracted teeth had full cast crowns cemented with either a zinc phosphate, a glass ionomer, or a resin cement, and simulated diving to 30 m (3.0 atmospheres) was performed. During simulated diving, the teeth were pressure cycled 15 times to 3 atmospheres and microleakage was monitored. The force required to dislodge the crown was then tested; a significant difference was found between the zinc phosphate and the glass ionomer cement groups (p < 0.01). No difference was found between the resin cement groups. Microleakage was also detected in the zinc phosphate and glass ionomer cement groups and was found to occur sooner, and to a greater extent with zinc phosphate. No microleakage was detected in the resin cement experimental group. This study showed that the retention of full cast crowns to extracted teeth is reduced after pressure cycling and that microleakage does occur if the crowns are cemented with either zinc phosphate cement or glass ionomer cement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.