The motion of a charged satellite subjected to the Earth's magnetic field is considered. Lorentz force, which acts on charged particle when it is moving through the magnetic field, provides a new concepts of propellant-less electromagnetic propulsion. We derive a dynamical model of a charged spacecraft including the effect of Lorentz force in the vicinity of circular and elliptic orbit and consider its application to formation flight. Based on Hill-Clohessy-Wiltshire equations and Tschauner-Hempel equations, analytical approximations for the relative motion in Earth orbit are obtained. The analysis based on linearized equations in the equatorial case show that the stability of the periodic solutions. Numerical simulations revealed that the periodic solutions which are useful for the formation are obtained for both circular and elliptic reference orbits.The control strategy for the propellantless rendezvous and reconfiguration are developed.
The goal of total body irradiation (TBI) is to deliver a dose to the whole body with uniformity within ±10%. The purpose of this study was to establish the technique of TBI using plastic bead bags. A lifting TBI bed, Model ORP-TBI-MN, was used. The space between the patient’s body and the acrylic walls of the bed was filled with polyacetal bead bags. Patients were irradiated by a 10 MV photon beam with a source to mid-plane distance of 400 cm. The monitor unit (MU) was calculated by dose-per-MU, tissue-phantom-ratio and a spoiler factor measured in solid water using an ionization chamber. The phantom-scatter correction factor, off-center ratio and the effective density of the beads were also measured. Diode detectors were used for in vivo dosimetry (IVD). The effective density of the beads was 0.90 ± 0.09. The point doses calculated in an I’mRT phantom with and without heterogeneity material showed good agreement, with measurements within 3%. An end-to-end test was performed using a RANDO phantom. The mean ± SD (range) of the differences between the calculated and IVD-measured mid-plane doses was 1.1 ± 4.8% (−5.9 to 5.0%). The differences between the IVD-measured doses and the doses calculated with Acuros XB of the Eclipse treatment planning system (TPS) were within 5%. For two patients treated with this method, the differences between the calculated and IVD-measured doses were within ±6% when excluding the chest region. We have established the technique of TBI using plastic bead bags. The TPS may be useful to roughly estimate patient dose.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.