We report two cases of ruptured basilar bifurcation aneurysm associated with a persistent primitive hypoglossal artery. Angiograms revealed low-positioned aneurysms; in both cases bilateral vertebral arteries and posterior communicating arteries were hypoplastic or aplastic. Both aneurysms were successfully clipped via subtemporal transtentorial approach through the craniotomy ipsilateral to the side of the primitive hypoglossal artery. The ipsilateral craniotomy and exposure of the cervical carotid artery were helpful for obtaining the proximal control of the basilar artery needed to perform the clipping procedure with safety.
We treated a patient with neurosarcoidosis, which caused the syndrome of inappropriate secretion of antidiuretic hormone (SIADH), in whom diagnosis was performed using neuroendoscopy. The patient was a 56-year-old female who was hospitalized for hyponatremia and diagnosed with SIADH based on a detailed examination. During the course, she developed impaired consciousness due to acute hydrocephalus, which improved after ventricular drainage. Head magnetic resonance imaging (MRI) confirmed nodular lesions at the floor of the third ventricle and the cerebral aqueduct. Neuroendoscopic biopsy led to the diagnosis of neurosarcoidosis. Her hyponatremia improved after steroid therapy. Neurosarcoidosis can cause SIADH, and complication of hydrocephalus may lead to a poor prognosis. Neuroendoscopy appears to be effective for the diagnosis of neurosarcoidosis with hydrocephalus and helps in deciding the treatment modality.
A newly developed head fixation for intraoperative computerized tomographic (IOCT) scanning is presented. The system is developed based on the head holder of multipurpose head frame and is made of two kinds of advanced engineering material; carbon fiber reinforced plastic for head holder and frames, polyamide-imide polymer for joints, screws, and head pin. Clinical tests including autoclaving and sterilization were performed and revealed all materials had sufficient strength for clinical use. This fixation system enables us to increase the efficacy of IOCT scanning during open-field neurosurgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.