Objectives
To determine the ideal angle for insertion of laparoscopic instruments at Palmer's Point.
Study Design
Abdominal magnetic resonance images were reviewed for 75 women between ages 18 and 50 years old. The distance from the skin to the retroperitoneal structures were determined perpendicular to the spine and angled 45 ° caudally.
Results
When instruments are inserted perpendicular to the skin in the axial plane and peritoneum perpendicular to the spine, the distance from skin to posterior was 10.0 ± 0.2 cm and to the aorta was 11.3 ± 0.2 cm. If instruments are inserted at an angle 45° caudally, this distance increased to 16.6 ± 0.2 cm.
Conclusions
When Inserting laparoscopic instruments at Palmer's Point, insertion perpendicular to the skin in the axial plane and angled 45° caudally in relation to the spine offers an increased margin of safety compared to insertion perpendicular to the spine, particularly in thin women.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.