Treatment of PCs with Mirasol leads to the amplification of VASP Ser-239 phosphorylation, which is linked to actin dynamics and regulation of integrin α(IIb) β(3) activation. This change offers one explanation for Mirasol's impact on PLT in vitro quality measures. The Ser-239 phosphorylation level of VASP might be a useful protein marker for riboflavin and UV light-mediated PLT compromise.
Plasma and cryoprecipitate products, prepared using methods in which the plasma is frozen close to 24 hours after collection, meet current quality standards. The longer WB storage time has been implemented into general use in Canada.
BACKGROUNDIn high-volume processing environments, manual breakage of in-line closures can result in repetitive strain injury (RSI). Furthermore, these closures may be incorrectly opened causing shear-induced hemolysis. To overcome the variability of in-line closure use and minimize RSI, Fresenius Kabi developed a new in-line closure, the CompoFlow, with mechanical openers.STUDY DESIGN AND METHODSThe consistency of the performance of the CompoFlow closure device was assessed, as was its effect on component quality. A total of 188 RBC units using CompoFlow blood bag systems and 43 using the standard bag systems were produced using the buffy coat manufacturing method. Twenty-six CompoFlow platelet (PLT) concentrates and 10 control concentrates were prepared from pools of four buffy coats. RBCs were assessed on Days 1, 21, and 42 for cellular variables and hemolysis. PLTs were assessed on Days 1, 3, and 7 for morphology, CD62P expression, glucose, lactate, and pH. A total of 308 closures were excised after processing and the apertures were measured using digital image analysis.RESULTSThe use of the CompoFlow device significantly improved the mean extraction time with 0.46 ± 0.11 sec/mL for the CompoFlow units and 0.52 ± 0.13 sec/mL for the control units. The CompoFlow closures showed a highly reproducible aperture after opening (coefficient of variation, 15%) and the device always remained opened. PLT and RBC products showed acceptable storage variables with no differences between CompoFlow and control.CONCLUSIONSThe CompoFlow closure devices improved the level of process control and processing time of blood component production with no negative effects on product quality.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.