Fetal compromise is associated with significant alterations in the fetal arterial and venous circulation. Significant changes in venous Doppler waveforms develop due to increased afterload and perhaps myocardial failure in late deterioration after fetal arterial redistribution is established and seem to be closely related to abnormal biophysical assessment findings. Therefore, Doppler investigation of the fetal venous circulation may play an important role in monitoring the redistributing growth retarded fetus and thereby may help to determine the optimal time for delivery.
The use of Doppler studies of the uterine arteries in the prediction of pre-eclampsia and intrauterine growth retardation has had mixed success. The introduction of color Doppler imaging and the use of the "notch' to define an abnormal waveform have helped to improve the predictive value of uterine artery Doppler screening. The aim of this study was to evaluate the use of uterine artery Doppler in a group of women of mixed race and parity. This study was a prospective, cross-sectional analysis of 1326 unselected women who were screened with continuous wave uterine Doppler at 19-21 weeks, as part of a fetal anomaly/dating scan. A total of 214 women with abnormal uterine artery waveforms (notching) were referred for assessment at 24 weeks; 191 attended and had color Doppler imaging/pulsed Doppler studies of both uterine arteries. Data from 185 pregnancies were suitable for analysis. There were abnormal uterine Doppler findings (uni- or bilateral notching) in 110 patients at 24 weeks; 48 had bilateral notching. The sensitivity of notching for the prediction of proteinuric pregnancy-induced hypertension (PPIH) was similar in primiparas (76.9%), multiparas (77.7%), African-Caribbean women (82.6%) and Caucasian women (71.4%). The sensitivity of bilateral notching for the prediction of PPIH requiring delivery before 34 weeks was 81.2%, and 57.6% for babies small for gestational age (SGA), with positive predictive values of 27% (PPIH), 31.2% (SGA) and 37.5% (any complication). Patients with persistent bilateral notching are particularly at risk of developing PPIH or delivering an SGA baby before 34 weeks' gestation; they warrant increased surveillance, and may be a group that could benefit from prophylactic therapies.
The aim of this study was to compare changes in Doppler ultrasound studies of the fetal circulation in normal pregnancies with a group of pregnancies complicated by proteinuric pregnancy-induced hypertension (PPIH), delivery of a small-for-gestational-age (SGA) baby, or both. A total of 167 uncomplicated pregnancies with a term delivery of an appropriately grown baby (AGA) were used to define the normal range. Altogether, 123 high-risk pregnancies with a known outcome constituted the study group. A color duplex ultrasound machine was used to perform biometry and fetal Doppler studies. Measurements obtained from the fetal circulation included the umbilical artery (UA) pulsatility index (PI), the middle cerebral artery (MCA) PI and time-averaged velocity (TAV), the thoracic aorta (AO) PI and TAV. In addition, the ratio between the MCA PI and UA PI, the MCA PI and the AO PI, and the product of the MCA PI and AO TAV were used in the analysis. A total of 105 pregnancies had a complicated outcome. They were divided into three categories: PPIH only (pregnancies complicated by PPIH with the delivery of an AGA fetus, n = 17), SGA only (delivery of an SGA baby, with no evidence of PPIH, n = 55), and PPIH + SGA (pregnancies complicated by pre-eclampsia and delivery of an SGA baby, n = 37). The PPIH + SGA group represented true clinical intrauterine growth retardation. Cross-sectional reference ranges were created using the observations from the normal group. z-scores (standard deviation from the mean of the normal range) of the last observations made before delivery were calculated for each of the vessel velocimetry measurements and ratios. The statistical significance of z-score values was calculated using analysis of variance. The MCA and UA PI values showed the greatest deviation for any single-vessel parameter. The ratios of fetal Doppler indices (MCA/UA PI ratio, MCA/AO PI ratio and the MCA PI/AO TAV index) demonstrated greater deviation from normal than any individual vessel. The UA PI z-score for PPIH+SGA delivering < 34 weeks gestation (2.92) was significantly greater than the z-score for PPIH+SGA delivering > or = 34 weeks (1.20, p < 0.05). Fetal Doppler indices, in particular ratios that include measurements obtained from the cerebral circulation, help in the recognition of the small fetus that is growth-retarded. At term, evidence of fetal hemodynamic redistribution may exist in the presence of a normal umbilical artery PI. Fetal Doppler indices provide information that is not readily obtained from more conventional tests of fetal well-being.(ABSTRACT TRUNCATED AT 400 WORDS)
ObjectiveTo determine the value of one-stop color Doppler imaging of the uterine arteries at the time of the 20-week anomaly scan, to select women at risk of developing pre-eclampsia and intrauterine growth restriction (IUGR).Patients and methods A total of 1022 unselected women had color Doppler imaging of both uterine arteries at the time of their dating/anomaly scan (19-21 weeks' gestation). The presence or absence of notching of the flow velocity waveform (FVW) was noted, and the resistance index (RI) was measured. The main outcome measures were pre-eclampsia, birth weight, placental abruption and stillbirth. ResultsThe outcome in 946 women (92.6%) was available for analysis. Of these, 216 (23%) had abnormal uterine artery Doppler studies, 117 (12.4%) with bilateral (right and left FVW) notches; 21 (2.2%) women developed preeclampsia, and 57 (6.0%) neonates were small for gestational age (SGA; < 5th centile), at birth. For women with bilateral notches the odds ratio (OR) for developing pre-eclampsia was 12.8 (95% confidence interval (CI) 5.3-30.8), and 52.6 (95% CI 6.4-430.1) for pre-eclampsia requiring delivery before 37 weeks' gestation. If the uterine artery Doppler studies were normal, the odds ratio for developing pre-eclampsia was 0.11 (95% CI 0.04-0.28), and 0.3 (95% CI 0.17-0.51) for the delivery of an SGA baby less than the 5th centile. In women with bilateral notches with mean RI greater than 0.55, the positive predictive value for the main outcome measures was 46%.Conclusion Women with normal uterine artery color/ pulsed Doppler studies at 20 weeks' gestation constitute a group that have a low risk of developing obstetric complications related to uteroplacental insufficiency. Women with high resistance in both uterine arteries (bilateral notches) have an increased risk of the subsequent development of such complications, in particular those requiring delivery before term. The addition of color Doppler imaging of the uterine arteries at the time of the routine 20-week dating/anomaly scan may be of use in determining the type and level of antenatal care that is offered to women.
This paper presents a fully-actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intra-operative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian motion module. The needle driver provides needle cannula translation and rotation (2-DOF) and stylet translation (1-DOF). A custom robot controller consisting of multiple piezoelectric motor drivers provides precision closed-loop control of piezoelectric motors and enables simultaneous robot motion and MR imaging. The developed modular robot control interface software performs image-based registration, kinematics calculation, and exchanges robot commands and coordinates between the navigation software and the robot controller with a new implementation of the open network communication protocol OpenIGTLink. Comprehensive compatibility of the robot is evaluated inside a 3-Tesla MRI scanner using standard imaging sequences and the signal-to-noise ratio (SNR) loss is limited to 15%. The image deterioration due to the present and motion of robot demonstrates unobservable image interference. Twenty-five targeted needle placements inside gelatin phantoms utilizing an 18-gauge ceramic needle demonstrated 0.87 mm root mean square (RMS) error in 3D Euclidean distance based on MRI volume segmentation of the image-guided robotic needle placement procedure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.