Mechanical versus bioprosthetic valves in chronic dialysis: a systematic review and meta-analysisBackground: Many patients with end-stage kidney disease (ESKD) have valvular heart disease requiring surgery. The optimal prosthetic valve is not established in this population. We performed a systematic review and meta-analysis to assess outcomes of patients with dialysis-dependent ESKD who received mechanical or bioprosthetic valves. Methods:We searched Cochrane Central, Medline and Embase from inception to January 2020. We performed screening, full-text assessment, risk of bias and data collection, independently and in duplicate. Data were pooled using a random-effects model. Results:We identified 28 observational studies (n = 9857 patients, including 6680 with mechanical valves and 3717 with bioprosthetic valves) with a median follow-up of 3.45 years. Twenty-two studies were at high risk of bias and 1 was at critical risk of bias from confounding. Certainty in evidence was very low for all outcomes except bleeding. Mechanical valves were associated with reduced mortality at 30 days (relative risk [RR] 0.79, 95% confidence interval [CI] 0.65-0.97, I 2 = 0, absolute effect 27 fewer deaths per 1000) and at 6 or more years (mean 9.7 yr, RR 0.83, 95% CI 0.72-0.96, I 2 = 79%, absolute effect 145 fewer deaths per 1000), but increased bleeding (incidence rate ratio [IRR] 2.46, 95% CI 1.41-4.27, I 2 = 59%, absolute effect 91 more events per 1000) and stroke (IRR 1.63, 95% CI 1.21-2.20, I 2 = 0%, absolute effect 25 more events per 1000). Conclusion: Mechanical valves were associated with reduced mortality, but increased rate of bleeding and stroke. Given very low certainty for evidence of mortality and stroke outcomes, patients and clinicians may choose prosthetic valves based on factors such as bleeding risk and valve longevity. Study registration: PROSPERO no. CRD42017081863 Contexte : De nombreux patients souffrant d'insuffisance rénale terminale (IRT) présentent une valvulopathie nécessitant une intervention chirurgicale. On ignore quelle est la valve prothétique optimale chez cette population. Nous avons effectué un examen systématique et une méta-analyse pour évaluer les résultats des patients atteints d'IRT dialysés ayant reçu une valvule mécanique ou une bioprothèse valvulaire.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.