Tungsten-Titanium-Nitrogen (W-Ti-N) thin film, 1.1 μm in thickness, was deposited on Aluminium-Silicon (Al-Si) and stainless steel substrates using the Physical Vapour Deposition (PVD) sputtering system in order to study a new way to improve the tribological properties on engines piston skirts. Tribological test results showed very interesting friction coefficient and wear rates compared to uncoated piston skirt samples. The average value of the friction coefficient was approximately six times lower than that of the uncoated piston skirt samples. Wear rate was considerably lower. In addition W-Ti-N showed interesting corrosion behaviour.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.