Indoor positioning and tracking systems have become enormous issue in location awareness computing due to its improvement of location detection and positioning identification. The locations are normally detected using position technologies such as Global Positioning System, radio frequency identification, Bluetooth Beacon, Wi-Fi fingerprinting, pedometer and so on. This research presents an indoor positioning system based on Bluetooth low energy 4.0 Beacons; we have implemented Bluetooth signal strength for tracking the specific location and detect the movement of user through Android application platform. Bluetooth low energy was addressed to be an experiment technique to set up into the real environment of interior the building. The signal strength of beacons is evaluated and measured the quality of accuracy as well as the improvement of provide raw data from Beacons to the system to get better performance of the direction map and precise distance from current location to desire’s positioning. A smartphone application detects the location-based Bluetooth signal strength accurately and can be achieved the destination by provided direction map and distance perfectly.
The COVID-19 causes wide impact in business operation. The enterprise must mitigate the risk of COVID-19 spread in its environment. The monitoring of body temperature for employees can be applied as a method to prevent COVID-19 spread. However, the monitoring system must consider several factors such as contactless system, accountable, and simple. The integration between IR temperature sensor and attendance system based on ESP32 is able to provide those need. The use of proximity, IR, and RFID sensor is affordable to detect body temperature properly within 10 cm. The proposed system provides notification if user gets fever or suspect of COVID-19 by detecting the body temperature. The accuracy of sensor is adequate. It is based on the comparison testing between proposed system with body thermometer where the testing is performed 30 times for each condition. In order to deduce the comparison result, this study uses analysis of variance method. The analysis produces F-critical (4,006) greater than F-value (0,022) where it means that the proposed system and body thermometer have similar testing result. It is shown good accuracy for the proposed system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.