In this study, an investigation was made of the performance of a Trombe wall of classical structure used together with a heat store. Most Trombe walls are able to supply the heating needs of a space to which they are connected without the need for extra heating at times when the sun is shining. However, the heat obtained from the Trombe wall can be in excess of needs at such times, and measures must be taken to provide ventilation to the heated space. It is thought that the heat energy can be used more efficiently and productively by storing the excess heat outside the building and using it inside the building when there is no sunlight. To this purpose, a tank full of water and marble was built as a heat store as an alternative to the general Trombe wall design, and an attempt was made to minimise heat losses by burying it in the ground. It was concluded that in place of a traditional Trombe wall system using a massive wall heat store, a heat store could be constructed in a different position and with different materials. The Trombe wall system which was developed and tested met up to 30% of the energy needed for heating and cooling the building, and reduced the architectural and static disadvantages of Trombe wall systems. As a result of the study, it was seen that where a standard reinforced concrete wall could supply heat to the inside for 7 hours and 12 minutes, the figure for a wall made of paraffin wax was 8 hours and 55 minutes. In the same study, the heat storage thickness of a reinforced concrete wall was calculated as 20 cm, while that of a paraffin wax wall was calculated as 5 cm.
In this study, the reason for erosion-corrosion of drinking or mains water in the faucet was investigated by computational fluid dynamics. Pipes used in homes, the service sector, and industry are responsible for transporting different types of fluids from one place to another. Considering the faucet design, the SolidWorks program was used for 3D studies. In-faucet flow analyses were performed using Ansys Fluent, a computational fluid dynamics program based on the finite volume method. In the analyses, lime particles were chosen. At the end of the analysis, the amount of erosion in the faucet was obtained.
The Mediterranean Sea is considered an aquatic biodiversity hotspot that hosts approximately 782 fish species and 72 of them are categorized as endemic. However, non-native species introductions that are of natural or human-mediated origin have posed a major threat to the biodiversity of the Mediterranean Sea which is showing high rates of endemism. Here, we represent historical and recent updated data alien (Champsodon nudivittis, Nemipterus randalli, Pterois miles, Scarus ghobban, Scomberomorus commerson), neonative (Seriola fasciata, Sphoeroides pachygaster) fishes spreading on the Aegean Sea.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.