ABSTRACT.Purpose: To evaluate the efficacy and safety of intravitreal bevacizumab (IVB) in eyes with neovascular glaucoma (NVG) undergoing Ahmed glaucoma valve (AGV) implantation. Methods: This was a multicentre, prospective, randomized clinical trial that enrolled 40 patients with uncontrolled neovascular glaucoma that had undergone panretinal photocoagulation and required glaucoma drainage device implantation. Patients were randomized to receive IVB (1.25 mg) or not during Ahmed valve implant surgery. Injections were administered intra-operatively, and 4 and 8 weeks after surgery. Results: After a mean follow-up of 2.25 AE 0.67 years (range 1.5-3 years), both groups showed a significant decrease in IOP (p < 0.05). There was no difference in IOP between groups except at the 18-month interval, when IOP in IVB group was significantly lower (14.57 AE 1.72 mmHg vs. 18.37 AE 1.06 mmHg -p = 0.0002). There was no difference in survival success rates between groups. At 24 months, there was a trend to patients treated with IVB using less antiglaucoma medications than the control group (p = 0.0648). Complete regression of rubeosis iridis was significantly more frequent in the IVB group (80%) than in the control group (25%) (p = 0.0015). Conclusions: Intravitreal bevacizumab may lead to regression of new vessels both in the iris and in the anterior chamber angle in patients with neovascular glaucoma undergoing Ahmed glaucoma valve implantation. There is a trend to slightly lower IOPs and number of medications with IVB use during AGV implantation for neovascular glaucoma.
Purpose. To investigate the diagnostic accuracy of machine learning classifiers (MLCs) using retinal nerve fiber layer (RNFL) and optic nerve (ON) parameters obtained with spectral domain optical coherence tomography (SD-OCT). Methods. Fifty-seven patients with early to moderate primary open angle glaucoma and 46 healthy patients were recruited. All 103 patients underwent a complete ophthalmological examination, achromatic standard automated perimetry, and imaging with SD-OCT. Receiver operating characteristic (ROC) curves were built for RNFL and ON parameters. Ten MLCs were tested. Areas under ROC curves (aROCs) obtained for each SD-OCT parameter and MLC were compared. Results. The mean age was 56.5 ± 8.9 years for healthy individuals and 59.9 ± 9.0 years for glaucoma patients (P = 0.054). Mean deviation values were −1.4 dB for healthy individuals and −4.0 dB for glaucoma patients (P < 0.001). SD-OCT parameters with the greatest aROCs were cup/disc area ratio (0.846) and average cup/disc (0.843). aROCs obtained with classifiers varied from 0.687 (CTREE) to 0.877 (RAN). The aROC obtained with RAN (0.877) was not significantly different from the aROC obtained with the best single SD-OCT parameter (0.846) (P = 0.542). Conclusion. MLCs showed good accuracy but did not improve the sensitivity and specificity of SD-OCT for the diagnosis of glaucoma.
OBJECTIVES:To describe the indications for and visual outcomes of intrastromal corneal ring segment implantation.METHODS:A large retrospective case-series chart-review study was conducted using Sorocaba Ophthalmological Hospital medical records. This study included 1222 eyes (1196 patients) that were surgically treated between November 2009 and December 2012. The following preoperative data were collected: age, gender, type of medical care and funding source, surgical technique, best-corrected visual acuity, manifest sphere and cylinder refractive error, maximum and minimum central keratometry, and pachymetry measurements of the cornea at the thinnest point and at the ring channel. The postoperative best-corrected visual acuity and patient satisfaction were also determined. The cases were classified into six groups: four keratoconus groups (severe, advanced, moderate and mild), a pellucid marginal degeneration group and a post-graft irregular astigmatism group. This study was approved by the Brazilian Registry of Clinical Trials (UTN number 1111-1182-6181, TRIAL RBR-6S72RF).RESULTS:The age (mean±standard deviation) of the patients was 31.0±10.0 years. The most prevalent pathology was keratoconus (1147 eyes, 93.8%). A correlation was found between ectasia severity and medical assistance (p<0.001), and the most serious cases was treated by the Brazilian public health system. No complications were found in a total of 1155 surgeries, and after surgery, 959 patients were satisfied. Among the 164 dissatisfied patients, the majority failed to show improved best-corrected visual acuity.CONCLUSION:Patients in the public health system underwent surgical intervention for keratoconus later than those with private sources of funding. In the vast majority of operated cases, the patients reported improvements in vision.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.