The purpose of this study is the characteristics of the indicator electrode which has been coated with a membrane with XRD, SEM-EDS, UV-Vis and FTIR. Research has been carried out using XRD, SEM-EDS, UV-Vis and FTIR tests on immobilized indicator electrodes 0.0350 g PVA-Enzyme coated with PVC-KTpClPB 0.0120 g and 0.0500 g. The method used was the biosensor potentiometric method with the urease enzyme immobilization technique in PVA coated with PVC-KTpClPB. To see the difference in the absorbance spectrum pattern of each PVA-Enzyme composition coated with PVC-KTpClPB against wavelength with UV-Vis, PVA-Enzim solution as a reference and PVC-KTpClPB solution as the first analysis 0.0120 g and as the second analysis 0,0500 g. To see the PVA-enzyme membrane coated with PVC-KTpClPB in the two compositions above was characterized by FTIR and SEM-EDS. To see the indicator electrode that had been immobilized by PVA-enzyme coated with PVC-KTpClPB in the two compositions above, it was characterized by XRD. It was concluded that the best results were found on the immobilization indicator electrode of 0.0350 g PVA-Enzyme coated with 0.0350 g PVC-0.0500 g KTpClPB.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.