The reliability of an eddy current testing (ECT) inspection system depends upon the inspection technique and quality of analyst. In evaluating the integrity of a steam generator (SG) tube, degradation detection and sizing accuracy are considered performance measures of the nondestructive evaluation (NDE) system. A probability of detection (POD) model serves as a functional measure of the ability of an NDE system to detect degradation. It is one of the inputs in the operational assessment, and it is used to estimate the degradation during service via ECT of the SG tube. In this study, the POD functions of the inspection technique and analyst were obtained to quantitatively analyze the ECT bobbin probe for axial outside diameter stress corrosion cracks in SG tubes. This should serve to evaluate the integrity of the SG tubes. The depth and amplitude of defects were used as parameters of the POD model. Hit (detection) and miss (no detection) binary data obtained from destructive and nondestructive inspection of cracked tubes were also used.
Recently, the initiation of outside diameter stress corrosion cracking (ODSCC) at the tube support plate region of domestic steam generators (SG) with Alloy600 HTMA tubes has been increasing. As a result, SGs with Alloy600 HTMA tubes must be replaced early or are scheduled to be replaced prior to their designed lifetime. ODSCC is one of the biggest threats to the integrity of SG tubes. Therefore, the accurate evaluation of tube integrity to determine ODSCC is needed. Eddy current testing (ECT) is conducted periodically, and its results could be input as parameters for evaluating the integrity of SG tubes. The reliability of an ECT inspection system depends on the performance of the inspection technique and abilty of the analyst. The detection probability and ECT sizing error of degradation are considered to be the performance indices of a nondestructive evaluation (NDE) system. This paper introduces an optimized evaluation method for ECT, as well as the sizing error, including the analyst performance. This study was based on the results of a round robin program in which 10 inspection analysts from 5 different companies participated. The analysis of ECT sizing results was performed using a linear regression model relating the true defect size data to the measured ECT size data.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.