The aim of this work is to describe the behavior of three-phase inverters connected to a faulty grid by means of a parametric approach which gives rise to limaçon of Pascal curves and 3D figures formed by the injected currents during the fault. The analytical study is given in the complex form of the transformed Park variables, and the simulation results are obtained by means of MATLABTM. The results show that the parametric analysis can be an easy and useful tool to predict the behavior of three-phase inverters operating under voltage sags, with the aim of achieving fault ride-through (FRT) capability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.