This study aims to present a method for precooling bleed flow by water injection in the E-MATIANT cycle and to estimate its impact on the overall efficiency. The design parameters of the cycle are set up on the basis of the component technologies of today's state-of-the-art gas turbines with a turbine inlet temperature between 1100 and 1700°C. Several schemes of the E-MATIANT cycle are considered: with one, two and three combustion chambers. The optimal pressure ratio ranges for the considered turbine inlet temperatures are identified and a comparison with existing evaluations is made. For the optimal initial parameters, cycle net efficiency varies from 42.0 to 49.8%. A significant influence of turbine stage cooling model on optimal thermodynamic parameters and cycle efficiency is established. The maximum cycle efficiency is 44.0% considering cooling losses. The performance penalty due to the oxygen production and carbon dioxide capture is 20–22%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.