A benzamidine derivative from diminazene was tested for a novel activity: treatment of primary open‐angle glaucoma. This drug was incorporated into mucoadhesive polymeric inserts prepared using chitosan (Chs) and chondroitin sulfate (CS). Of current interest is the mucoadhesion, which increases the contact time with the ocular surface, resulting in improved bioavailability; also, the inserts are made to act as a prolonged release system. In the present work the inserts were prepared by the solvent casting method using different polymeric proportions (30:70, 50:50, 75:25% w/w Chs:CS and 100% Chs). Thermal analysis and infrared spectroscopy both demonstrated physical dispersion of the active drug. The most promising was the 50:50% Chs:CS which demonstrated that it was not fragile and has an in vitro release profile of up to 180 minutes. In addition, it presented greater adhesion strength in relation to the other formulations. These physicochemical results corroborate the in vivo tests performed. In this sense, we also demonstrated that the treatment with the 50:50% insert can control the intraocular pressure (IOP) for at least 3 weeks and prevents damage to the retinal ganglion cells (RGCs) compared to the placebo insert. Thus, this indicates thus that the new drug is quite viable and promising in glaucoma treatment.
The substance 4-Aminobenzamidine dihydrochloride (4-AD) is one of the degradation products of diminazene aceturate and has demonstrated antiglaucomatous potential. Glaucoma is the second leading cause of blindness worldwide; thus, new therapeutic alternatives must be studied, for example, the molecule 4-AD vehiculated into polymeric inserts for prolonged release. The present work aims to develop and validate an analytical method to quantify 4-AD in pharmaceutical ophthalmic forms. A HPLC was used with UV-Vis detector, at 290 ƞm and ACE ® C18 column (125 × 4.6 mm, 5 μm), in which the mobile phase consists of phosphate buffer (pH 7.4) and triethylamine (30 mmol/L), under an isocratic flow of 1.0 mL/min. The retention time of 3.2 minutes was observed. The method was developed and validated in accordance with ANVISA recommendations and ICH guides. The linearity range was established between the concentrations 5 and 25 μg/mL (correlation coefficient r = 0.993). The accuracy, repeatability, and intermediate precision tests obtained a relative standard deviation less than or equal to 5%. In addition, the method was considered selective, exact. and robust, with pH being its critical factor. Therefore, the HPLC analysis method is robust and can be used to quantify 4-AD in pharmaceutical forms for ocular application.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.