Epoxy quality contributes a great role in defining quality products of quad flat no lead multi row packages. In dealing with certain problems related to epoxy position shift caused by unoptimized design, innovation on the dispenser module is considered and focused at. This paper discusses the phenomenal issue of epoxy position shifting in die attach process and the solutions applied. The current design of dispenser module in die attach machine demonstrates flaws that need to be improved through design optimization. Innovative approach was applied, removing variables on the design that caused rejections during die attachment due to the shifted epoxy position. The improved design was able to address the issue as projected on the study, and helps not only the epoxy position performance, but also the set-up time of epoxy during syringe replacement. This design can be adapted by other manufacturing for process improvement and robustness.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.