Objective: Since its first report, video-assisted thoracic surgery (VATS) lung lobectomy was carried out with the use of conventional surgical instruments, used in laparoscopy and open thoracotomy. These instruments are expensive, not standardized and there are a variety of models and manufacturers. The aim of this study was to determine the impact of the use of these instruments on the experimental pulmonary lobectomy. Methods: We used a modified surgical simulator that uses a porcine heart-lung block filled with tomato sauce, and tested specific (Group 1) and regular (Group 2) instruments. Each group includes 15 experiments. Results: The median total time, excluding the time spent to correct the lesions, was 45.08 and 45.81 minutes, respectively in Group 1 and Group 2. There was no statistical difference between the total times (p=0.58). The only statistically different was seen for partial times regarding the elapsed time to cut and suture of lung fissures (p=0.03 and 0.04, respectively). There were more direct lesions and indirect leaks in Group 2, but without statistical significance (p=1.000 and p=0.203, respectively). The mean time spent for the diagnosis and correction of these events was 1.77 minutes with a standard deviation of 1.18 for Group 1 and 2.72 ± 1.11 minutes for Group 2 (p=0.044). Conclusion: The use of minimally invasive instruments is not associated with time improvement spent with experimental video-assisted lung lobectomy and does not lead to a faster or safer surgery. The use of VATS instruments makes correction of adverse events faster when they occur.
ResumoA fixação interna da clavícula utilizando-se fios metálicos somente é recomendada no caso de fraturas e luxações. Um caso de migração de fio de Kirschner empregado com essa finalidade é relatado. O raio X simples e a tomografia computadorizada confirmaram a migração intra-espinhal no nível T2-T3, aparentemente transfixando a medula espinhal. O tratamento foi realizado por exploração cirúrgica com anestesia local. O fio foi retirado por tração longitudinal com uma incisão supraclavicular. A literatura médica recomenda que esses fios tenham a extremidade dobrada para prevenir a migração. O fio deve ser removido após seis semanas. Ocorrendo qualquer sinal de deslocamento o fio deve ser removido antes desse período.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.