A large-mode-area polymer photonic crystal fiber made of polymethyl methacrylate with the cladding having only one layer of air holes near the edge of the fiber is designed and proposed to be used in surface plasmon resonance sensors. In such sensor, a nanoscale metal film and analyte can be deposited on the outer side of the fiber instead of coating or filling in the holes of the conventional PCF, which make the real time detection with high sensitivity easily to realize. Moreover, it is relatively stable to changes of the amount and the diameter of air holes, which is very beneficial for sensor fabrication and sensing applications. Numerical simulation results show that under the conditions of the similar spectral and intensity sensitivity of 8.3 × 10−5–9.4 × 10−5
RIU, the confinement loss can be increased dramatically.
Optical coherence tomography (OCT) has been extensively used as noninvasive tool for biological tissues owing to its three-dimensional imaging ability and high axial resolution. OCT quality assurance is vital in these occasions to keep the reliability and accuracy in medical diagnosis. It is necessary to develop a calibration tool for OCT product manufacture, calibration, and quality control. A practical tool is demanded in the OCT quality control and calibration of OCT. So far, there is no such a practical tool that can test all the key parameters of OCT. We design and fabricate a model eye tool, which has this function. The model eye comprises a doublet lens, a single filament, a piece of glass plate and the microsphere-embedded phantom. The doublets lens is bonded by two pieces of planoconvex lenses in the plane position. The first lens focuses parallel light onto the rear surface of the second lens. The rear surface marked with concentric circles serves as retina to measure the angular field of view (FOV). The small flat surface on the peak of the second lens is used to test signal to noise ratio (SNR). The single filament with 125[Formula: see text][Formula: see text]m diameter is used to check the co-alignment of preview and OCT scan. The empty chamber between the small plane of the second lens and the first surface of glass plate is used to measure the depth scaling of the OCT. The microspheres of 1[Formula: see text][Formula: see text]m diameter distributed uniformly in the phantom, which can test the lateral and the axial resolution of OCT equipment. Experimental results are presented to show the validity of the proposed tool. It is shown that the tool is able to be used in the calibration and quality control of retinal OCT.
We report the system design and experimental verification of an intracavity absorption multiplexed sensor network with hollow core photonic crystal fiber (HCPCF) sensors and dense wavelength division multiplexing (DWDM) filters. Compared with fiber Bragg grating (FBG), it is easier for the DWDM to accomplish a stable output. We realize the concentration detection of three gas cells filled with acetylene. The sensitivity is up to 100 ppmV at 1536.71 nm. Voltage gradient is firstly used to optimize the intracavity sensor network enhancing the detection efficiency up to 6.5 times. To the best of our knowledge, DWDM is firstly used as a wavelength division multiplexing device to realize intracavity absorption multiplexed sensor network. It make it possible to realize high capacity intracavity sensor network via multiplexed technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.