A novel method for the detection of trace estradiol valerate (EV) in pharmaceutical preparations and human serum was developed by inhibition of luminol chemiluminescence (CL) by estradiol valerate on the zinc deuteroporphyrin (ZnDP)-enhanced luminol-K3 Fe(CN)6 chemiluminescence system. Under optimized experimental conditions, CL intensity and concentration of estradiol valerate had a good linear relationship in the ranges of 8.0 × 10(-8) to 1.0 × 10(-5) g/mL. Detection limit (3σ) was estimated to be 3.5 × 10(-8) g/mL. The proposed method was applied successfully for the determination of estradiol valerate in pharmaceutical preparations and human serum and recoveries were 97.0-105.0% and 95.5-106.0%, respectively. The possible mechanism of the CL system is discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.