Results of an international intercomparison study (CCQM-P86) to assess the analytical capabilities of national metrology institutes (NMIs) and selected expert laboratories worldwide to accurately quantitate the mass fraction of selenomethionine (SeMet) and total Se in pharmaceutical tablets of selenised-yeast supplements (produced by Pharma Nord, Denmark) are presented. The study, jointly coordinated by LGC Ltd., UK, and the Institute for National Measurement Standards, National Research Council of Canada (NRCC), was conducted under the auspices of the Comité Consultatif pour la Quantité de Matière (CCQM) Inorganic Analysis Working Group and involved 15 laboratories (from 12 countries), of which ten were NMIs. Apart from a protocol for determination of moisture content and the provision of the certified reference material (CRM) SELM-1 to be used as the quality control sample, no sample preparation/extraction method was prescribed. A variety of approaches was thus used, including single-step and multiple-step enzymatic hydrolysis, enzymatic probe sonication and hydrolysis with methanesulfonic acid for SeMet, as well as microwave-assisted acid digestion and enzymatic probe sonication for total Se. For total Se, detection techniques included inductively coupled plasma (ICP) mass spectrometry (MS) with external calibration, standard additions or isotope dilution MS (IDMS), inductively coupled plasma optical emission spectrometry , flame atomic absorption spectrometry and instrumental neutron activation analysis. For determination of SeMet in the tablets, five NMIs and three academic/institute laboratories (of a total of five) relied upon measurements using IDMS. For species-specific IDMS measurements, an isotopically enriched standard of SeMet (76Se-enriched SeMet) was made available. A novel aspect of this study relies on the approach used to distinguish any errors which arise during analysis of a SeMet calibration solution from those which occur during analysis of the matrix. To help those participants undertaking SeMet analysis to do this, a blind sample in the form of a standard solution of natural abundance SeMet in 0.1 M HCl (with an expected value of 956 mg kg(-1) SeMet) was provided. Both high-performance liquid chromatography (HPLC)-ICP-MS or gas chromatography (GC)-ICP-MS and GC-MS techniques were used for quantitation of SeMet. Several advances in analytical methods for determination of SeMet were identified, including the combined use of double IDMS with HPLC-ICP-MS following extraction with methanesulfonic acid and simplified two-step enzymatic hydrolysis with protease/lipase/driselase followed by HPLC-ICP-IDMS, both using a species-specific IDMS approach. Overall, satisfactory agreement amongst participants was achieved; results averaged 337.6 mg kg(-1) (n = 13, with a standard deviation of 9.7 mg kg(-1)) and 561.5 mg kg(-1) (n = 11, with a standard deviation of 44.3 mg kg(-1)) with median values of 337.6 and 575.0 mg kg(-1) for total Se and SeMet, respectively. Recovery of SeMet from SELM-1 averaged 95...
Total arsenic in nine species Antarctic macro algae has been measured, by electrothermal atomic absorption spectrometry using a Pd/Mg(NO3)2 matrix modifier, to determine their capacity to accumulate the element. Macro algae were collected in February during the 2000 austral summer season at Jubany Station (Argentinean scientific station) around Potter Cove, King George Island. An optimized two-step microwave (MW) program was used to digest the samples. Dried samples were treated with HNO3, H2O2, and HF, left overnight, then subjected to the first MW cycle. After cooling HNO3 and HClO4 were added and samples were subjected to the second MW cycle of digestion treatment. The effect of power and time on As recovery was examined. The analytical features of the method were: detection limit, 0.24 microg g(-1) (dry mass); precision (RSD), 4.2-5.7%; recovery 91-105%. A wide range of As-retention capacity (41.0-447 microg g(-1) dry mass) was observed among the different species. The highest levels of As were found in Phaeurus antarcticus (447 microg g(-1) dry mass). This organism satisfies several prerequisites to be considered for consideration as a biomonitor in future studies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.