Six auxin-type herbicides in air, rain and dew samples were extracted and derivatised t o the volatile 2,3,4,5,6-pentafluorobenzyl derivatives, followed by confirmation and quantification using gas chromatography with ion trap detection. The extraction recovery of 2,4-dichlorophenoxyethanoic acid and its dimethylamine salt from fortified tubes (air samples), distilled water (rain samples) and filter-paper (dew samples) was acceptable. The powerful selectivity of the gas chromatograph with ion trap detection allowed quantification of the herbicides irrespective of extraneous peaks present at the same retention time. In addition, automatic confirmation was accomplished without using a mass spectrometer. For 2,4-dichlorophenoxyethanoic acid, the method has a limit of detection of 0.72 ng m-3 in air, 8.39 ng 1-1 in rain water and 5.21 ng per 491 cm2 of exposed filter-paper (dew sample).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.