Background: Vertebral compression fractures are common among the elderly, which is conditioned by osteoporosis. They cause back pain and limit the patient’s activities. The Kiva® VCF Treatment System is a new device to treat vertebral compression fractures. Compared to other methods, the utilization of the Kiva System reduces the risk for complications and delivers improvements in back pain reduction and functionality. Objectives: Evaluation of safety and effectiveness of the Kiva System in comparison to balloon kyphoplasty on the basis of matched pairs. Methods: 52 patients (47 - 89 years, 68 fractures) were treated with balloon kyphoplasty or with the new Kiva System. Back pain and impairment of motility were assessed preoperatively and 6 months postoperatively, with the Visual Analog Scale (VAS) and Oswestry Disability Index (ODI). The operation time and cement extravasation were recorded. Control radiographs were evaluated for new fractures and vertebral heights. Results: Mean VAS values in both groups improved from preoperatively 87.6 ± 12.8 and 83.1 ± 14.9 to 10.8 ± 20.8 and 24.6 ± 11.0 6 months after the treatment. The improvement after 6 months in the Kiva group was significantly better than in the balloon kyphoplasty group (P < 0.0001). Mean ODI scores in both groups also improved from 68.7% ± 15.8% in the Kiva group and 80.6% ± 8.6% in the balloon kyphoplasty group preoperatively to 24.8 ± 18.6% and 33.2 ± 6.3% 6 months after treatment. The mean operation time for the Kiva group was 12.7 ± 3.7 minutes per vertebra and cement leakage occurred in 6 patients. The mean operation time for the balloon kyphoplasty group was 34.1 ± 7.0 minutes per vertebra and cement leakage occurred in 8 patients. Anterior and mid vertebral height in the Kiva group increased from preoperatively 21.06 ± 7.44 mm and 18.36 ± 5.64 mm to postoperatively 22.41 ± 7.14 mm and 20.41 ± 6.00 mm. Anterior and mid vertebral height in the balloon kyphoplasty group increased from preoperatively 21.68 ± 2.06 mm and 21.97 ± 1.78 mm to postoperatively 25.09 ± 2.54 mm and 25.29 ± 2.10 mm. Vertebral height restoration could be therefore maintained with both procedures for 6 months. In the Kiva group 2 cases of nonadjacent fractures and one case of adjacent fractures were observed. In the balloon kyphoplasty group 9 cases of adjacent, as well as 5 cases of nonadjacent, fractures were observed. In the Kiva group significant fewer fractures occurred. Limitations: The study includes only 26 patients for each procedure, which were compared on the basis of matched pairs. Conclusion: The Kiva System appears to be a safe and effective procedure for the treatment of vertebral compression fractures. Six months after treatment with the Kiva System, better VAS values than the values after the treatment with balloon kyphoplasty were recorded. Reduction in functional impairment was as successful as it was after balloon kyphoplasty. Vertebral height restoration was observed in both groups, which was sustained for 6 months. The risk of cement extravasation during the Kiva Treatment is nearly the same as in balloon kyphoplasty; however, it requires a shorter operation time and produces fewer new fractures. Key words: Vertebral compression fracture, Kiva, kyphoplasty, vertebral augmentation, osteoporosis, back pain
Rationale:Pravastatin has emerged for prevention and treatment of preeclampsia; no reports are available on pravastatin and HELLP (hemolysis, elevated liver enzymes and low platelets) syndrome.Patient concerns:The first pregnancy necessitated termination of pregnancy at gestational age (GA) 20+5 for HELLP. Intrauterine fetal death at GA 22+5 occurred in the second pregnancy, whilst on temporizing management of HELLP.Diagnoses:Severe, recurrent early-onset HELLP syndrome.Interventions:In her fourth pregnancy, pravastatin was commenced at GA 13.Outcomes:The course of pregnancy was uncomplicated, and a healthy, appropriate for gestational age fetus was delivered at term.Lessons:Pravastatin may be effective in prevention of HELLP. The hepatic uptake may be of particular advantage.
Radiofrequency kyphoplasty offers a secure superiority over conservative treatment regarding clinical efficacy. In addition, the fractured vertebrae can be better targeted and erected, a longer processing time of the cement is ensured, a high interdigitation of the cement with the bone is guaranteed, the rate of cement leakage is low, the risk of radiation for the surgeon is minimised, and the operation time is shortened.
Background/Aim: Endometrial carcinoma (EC) is one of the most common gynecological cancers in the Western Hemisphere. Nevertheless, there are not enough appropriate treatment options, especially for advanced stages. The immune checkpoint blockade represents a promising alternative to established cancer therapies by suppressing the immune-inhibitory activity of the immune checkpoint factors programmed cell death-1 (PD-1) and programmed cell death ligand-1 (PD-L1). In the present study, we characterized the clinical relevance of the biomarker PD-L1 expression in terms of its prognostic capabilities in EC. Patients and Methods: Tumor tissue samples from 87 EC patients were retrospectively analyzed by immunohistochemistry (PD-L1, p16, estrogen receptor, progesterone receptor, HER2/neu, Ki-67, CD3, CD20, CD68). Results: A total of 17.3% of EC patients were PD-L1 positive. PD-L1 status did not represent a suitable prognostic marker in EC, but correlated with T3/T4stage, positive lymph node status, p16 expression, and absence of estrogen and progesterone receptor. PD-L1 positive tissues showed increased infiltration with lymphocytes, monocytes, and macrophages, although not statistically significant in every case. Conclusion: In EC, PD-L1 expression has no prognostic significance, but correlates with other oncogenic factors and indicates increased infiltration of the tumor with immune cells. Thus, PD-1/PD-L1 immunecheckpoint blockade seems to be very promising, at least in a subset of EC patients.
Combining posterior fixation with RF-TVA leads to better results of VAS and ODI, whereas the vertebral height restoration was favorable for patients treated with BKP. Cement leakage was comparable between both groups. It was asymptomatic and within reported ranges. Limitations of this study are the patient number and different stabilization instrumentation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.