The aim of the present study was to evaluate the mechanism of cerebrovascular autoregulation in patients with neurocardiogenic syncope using bilateral transcranial Doppler (TCD) monitoring during head upright tilt table testing (HUT). Two hundred and six patients were prospectively studied. One hundred and fifty-nine subjects (77%) had a prior history of syncope and 47 (23%) had presyncope. Ninety-nine patients (48%) had syncope or presyncope during HUT with a 76% fall in diastolic middle cerebral artery blood flow velocity (D-MCA-BFV). Systolic MCA-BFV (S-MCA-BFV) fell by 33%. Deepening of the dicrotic notch in the Doppler waveform always preceded the fall in D-MCA-BFV. Patients without syncope or presyncope (n=96) had smaller changes in cerebral blood flow velocities during HUT and only twenty-two subjects had transient deepening of the dicrotic notch. Eleven subjects had presyncope during HUT due to an exaggerated response to nitrates with progressive arterial hypotension without bradycardia and changes during TCD monitoring that were intermediate between positive and negative HUT. In conclusion, patients with neurocardiogenic syncope have changes in cerebral blood flow during the event. TCD monitoring during HUT helps to assess these alterations.
AF-nHB corrected bundle branch blocks in patients with severe conduction disturbances, even in those with dilated cardiomiopathy, outstanding from RVA. Also, the occurrence of cardiac memory during AF-nHB turned up as an observational finding of this study.
Runaway is an uncommon pacemaker dysfunction, characterized by fast and erratic spikes at non-physiological rates. This infrequent but potentially lethal failure mode may be related to low battery voltage. Four single chamber pacemaker patients were analyzed (Medtronic Minix ST 8330, Minneapolis, MN, had been implanted in two patients and two CPI Triumph VR 1124, St Paul, MN, in the other two). They had been admitted because of presyncopal episodes. Typical high rate stimuli at 2000 ppm alternating with pacing at 60-65 ppm were recorded in all ECGs. Lead system tests were normal. The pulse generators had to be replaced.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.