Introduction: Auto-generated 3-dimensional (3D) measurements based on weightbearing cone-beam computed tomography (CT) scan technology may allow for a more accurate hind- and midfoot assessment. The current study evaluated the reliability and clinical relevance of such measurements in patients with posttraumatic end-stage ankle osteoarthritis. Methods: Seventy-two patients treated at our institution for posttraumatic end-stage ankle osteoarthritis, with available weightbearing conventional radiographs and a cone-beam CT scan, were analyzed. Twenty healthy individuals aged between 40 and 70 years served as controls. Seven variables were measured on weightbearing conventional radiographs (2D) and compared to 3D measurements that were based on reconstructions from weightbearing cone-beam CT scans. The reliability of each measurement was calculated and subgroups formed according to commonly observed deformities. Results: Inter- and intraobserver reliability was superior for 3D compared to 2D measurements. The accuracy of 3D measurements performed on osteoarthritic ankles was similar to 3D measurements performed on healthy individuals. Thirty-three of the 72 included patients (46%) evidenced an inframalleolar compensation of a supramalleolar/intra-articular ankle deformity (78% = varus compensation; 22% = valgus compensation), whereas 24 of those 72 patients (33%) showed no compensation or a further increase of a supramalleolar/intra-articular ankle deformity (67% = varus deformity; 33% = valgus deformity). Conclusion: Auto-generated 3D measurements of the hind- and midfoot were found to be reliable in both healthy individuals and patients with posttraumatic end-stage ankle osteoarthritis. Such measurements may be crucial for a detailed understanding of the location and extent of hindfoot deformities, possibly impacting decision making in the treatment of end-stage ankle osteoarthritis. Level of Evidence: Level III, comparative study.
Background: Existing literature on the superiority of patient-specific instrumentation (PSI) in total ankle arthroplasty (TAA) over standard referencing (SR) is limited. Advantages presented include better implant alignment, shorter operating times, and increased accuracy of implant size prediction. The aim of this retrospective study was to analyze PSI in the hands of an experienced foot and ankle surgeon new to both PSI and SR for this specific implant, in regard to determining implant alignment, operative times, and radiologic short-term outcome and predicting implant size for tibial and talar components. Methods: Twenty-four patients undergoing TAA using PSI were compared to 25 patients using SR instrumentation. Outcome measures included alignment of the tibial component (α coronal plane, γ sagittal plane), the tibiotalar tilt (β), and the talar offset x on the sagittal view as well as the presence of radiolucent lines, operation time, and wound healing. Postoperative outcome was assessed at 6 weeks, 4 months, and 1 year postoperatively. Results: Implant positioning was similar in both groups, and no advantage in regard to the operative time could be seen when comparing TAA using PSI to SR. Implant size prediction was more reliable for the tibia than for the talus. Three patients (1 from the SR group and 2 from the PSI group) showed radiolucent lines around the tibial component. Two patients (both SR group) suffered delayed wound healing, albeit not requiring any additional measures. Conclusion: The PSI method did not show an advantage over SR in regard to positioning of the components or the duration of the surgery. The current study suggests that no initial advantage of PSI over SR are to be expected in standard total ankle replacement. Level of Evidence: Level III, retrospective study.
Category: Ankle; Ankle Arthritis; Hindfoot; Other Introduction/Purpose: Auto-generated 3-dimensional (3D) measurements based on weightbearing cone-beam computed tomography (CT) scan technology may allow for a more accurate hind- and midfoot assessment. The current study evaluated the reliability and clinical relevance of such measurements in patients with posttraumatic end-stage ankle osteoarthritis. Methods: Seventy-two patients treated at our institution for posttraumatic end-stage ankle osteoarthritis, with available weightbearing conventional radiographs and a cone-beam CT scan, were analyzed. Twenty healthy individuals aged between 40 and 70 years served as controls. Seven variables were measured on the conventional radiographs (2D) and compared to 3D measurements that were based on reconstructions from cone-beam CT scans. The reliability of each measurement was calculated and subgroups formed according to commonly observed deformities. Results: Inter- and intraobserver reliability was superior for 3D compared to 2D measurements. The accuracy of 3D measurements performed on osteoarthritic ankles was similar to 3D measurements performed on healthy individuals. Thirty-three of the 72 included patients (46%) evidenced an inframalleolar compensation of a supramalleolar/intra-articular ankle deformity (78% = varus compensation; 22% = valgus compensation), whereas 24 of those 72 patients (33%) showed no compensation or a further increase of a supramalleolar/intra-articular ankle deformity (67% = varus deformity; 33% = valgus deformity). Conclusion: Auto-generated 3D measurements of the hind- and midfoot are reliable in both healthy individuals and patients with posttraumatic end-stage ankle osteoarthritis. Such measurements may be crucial for a detailed understanding of the location and extent of hindfoot deformities, possibly impacting decision making in the treatment of end-stage ankle osteoarthritis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.