This paper addresses the wear characteristics of large aspect ratio (length-to-diameter) silicon microbearing systems using an enhanced experimental test rig. The test system is comprised of a rigid rotor which has been manually assembled onto a fixed hub to form the microbearing. CMOS-based lithographic and etching processes, including deep-reactive ion etching, are employed in the construction of the rotor and hub with length to diameter ratio of approximately 0.5 and radial clearance values in the range from 3.5 to 9.2 microns. The rotor is pneumatically driven by nitrogen gas at a constant supply pressure delivered through a rectangular microchannel.
A new methodology for measuring wear was developed by digitizing optical microscope images of the rotor system, and the rotor load was calculated from CFD models of the entire rotor-hub system. It was found that the tested silicon microbearings have an adhesion wear coefficient (based on the well-known Archard relation) which falls within a relatively narrow band bounded by previously published values for polysilicon materials tested at the macroscale and microscale.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.