†These authors contributed equally to this work. Hyperspectral imaging is a technique that allows for the creation of multi-color images. At terahertz wavelengths, it has emerged as a prominent tool for a number of applications, ranging from non-ionizing cancer diagnosis [1,2] and pharmaceutical characterization [3,4] to non-destructive artifact testing [5,6]. Contemporary terahertz imaging systems typically rely on non-linear optical down-conversion of a fiber-based near-infrared femtosecond laser, requiring complex optical systems. Here, we demonstrate hyperspectral imaging with chip-scale frequency combs based on terahertz quantum cascade lasers. The dual combs are free-running and emit coherent terahertz radiation that covers a bandwidth of 220 GHz at 3.4 THz with ~10 μW per line. The combination of the fast acquisition rate of dual-comb spectroscopy with the monolithic design, scalability, and chip-scale size of the combs is highly appealing for future imaging applications in biomedicine and in the pharmaceutical industry.
Since their inception, optical frequency combs have transformed a broad range of technical and scientific disciplines, spanning time keeping to navigation. Recently, dual comb spectroscopy has emerged as an attractive alternative to traditional Fourier transform spectroscopy, since it offers higher measurement sensitivity in a fraction of the time. Midwave infrared (mid-IR) frequency combs are especially promising as an effective means for probing the strong fundamental absorption lines of numerous chemical and biological agents. Mid-IR combs have been realized via frequency down-conversion of a near-IR comb, by optical pumping of a micro-resonator, and beyond 7 μm by four-wave mixing in a quantum cascade laser. In this work, we demonstrate an electrically-driven frequency comb source that spans more than 1 THz of bandwidth centered near 3.6 μm. This is achieved by passively mode-locking an interband cascade laser (ICL) with gain and saturable absorber sections monolithically integrated on the same chip. The new source will significantly enhance the capabilities of mid-IR multi-heterodyne frequency comb spectroscopy systems.
Dual-comb spectroscopy is a rapidly developing technique that enables moving parts-free, simultaneously broadband and high-resolution measurements with microseconds of acquisition time. However, for high sensitivity measurements and extended duration of operation, a coherent averaging procedure is essential. To date, most coherent averaging schemes require additional electro-optical components, which increase system complexity and cost. Instead, we propose an all-computational solution that is compatible with real-time architectures and allows for coherent averaging of spectra generated by free-running systems. The efficacy of the computational correction algorithm is demonstrated using spectra acquired with a THz quantum cascade laser-based dual-comb spectrometer. 2018-05-21
Fabry-Pérot (FP) quantum cascade lasers (QCLs) provide purely electronically controlled monolithic sources for broadband mid-infrared multiheterodyne spectroscopy (MHS), which benefits from the large gain bandwidth of the QCLs without sacrificing the narrowband properties commonly associated with the single mode distributed feedback variant. We demonstrate a FP-QCL based multiheterodyne spectrometer with a short-term noise-equivalent absorption of ~3×10-4 /√Hz, a mid-IR spectral coverage of 25 cm-1 , and very short acquisition time (10 μs) capability. The broadband potential is demonstrated by measuring absorption spectra of ammonia and isobutane under atmospheric pressure conditions. The stability of the system is enhanced by a two-stage active frequency interlocking procedure, where the two QCLs are prelocked with a slow feedback loop based on an analog frequency discriminator, followed by a high bandwidth optical phaselocked loop (OPLL). The locking system provides a relative frequency stability in the sub kHz range over seconds of integration time. The strength of the technique lies in the ability to acquire spectral information from all optical modes simultaneously and individually, which bodes for a versatile and cost effective spectrometer for mid-IR chemical gas sensing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.