The temperature dependences of resistivity and Hall coefficient of MgB2 and Mg0.93Li0.07B2 were measured, and the temperature dependence of cot-ΘH was calculated. The result of resistivity indicates that MgB2 and Mg0.93Li0.07B2 nearly have the same transition temperature. The-possible effect on transition temperature has been discussed. The measurement of Hall coefficient suggests the type of charge carriers is hole, and the Hall coefficient of Mg0.93Li0.07B2 becomes a little smaller compared with that of MgB2 which is attributed to Li doping . Both the decrease with increasing temperature-and-the temperature dependence of cotangent of Hall angle are proportional to the square of temperature.
Background: Application of sigma matrics across clinical laboratory diagnostic process enables identification of errors in methods together with quality goal index can help point out the cause of unacceptable process performance. We believe the analytical performance of the clinical biochemistry laboratory standards do not meet the required quality according to six sigma standards. Aim and Objective: The study aimed at performance evaluation of clinical biochemical laboratory analytical process using sigma metrics and quality goal index. Methods: Sigma (σ) for the 20 analytes performed on HITACHI 7600 - 110 was calculated based on absolute bias, total allowable error (TEa) and coefficient of variation (CV). Two level internal quality control data obtained retrospectively from December 2020 to May 2021 was used to calculate the coefficient of variation. Bias was obtained from six month external quality control data. Total allowable error was obtained from three different sources. Quality goal index (QGI) was calculated to identify the cause of unwanted analyte performance. Results: Different sigma scores were obtained for analytes on different total allowable error standard, only triglyceride showed world class performance along all the three total allowable error standards. However, creatine kinase & total bilirubin showed world class on clinical laboratory improvement amendment (CLIA) and biological variable database (BVD). On the other hand, glucose, and aspertate amino transferase had poor or unacceptable performance on all the total allowable error standards. Conclusion: Six sigma is an excellent tool in evaluating the quality performance of clinical biochemistry laboratory analytical process, quality goal index can help identify the problem and westgard rules can help design individual quality improvement strategy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.