Objectives: The aim of this study was to validate an ultrasound protocol for evaluating the anterolateral ligament of the knee. Methods: A Thiel technique cadaveric specimen was used to validate an optimal scanning position and develop an ultrasound protocol to evaluate the anterolateral ligament. Three musculoskeletal sonographers acquired short- and long-axis images of the anterolateral ligament in 36 knees from 18 healthy volunteers. Anterolateral ligament length, thickness, width, and distance between anterolateral ligament insertion and lateral tibia plateau were measured. Intraclass Correlation Coefficient (ICC) was calculated. Results: The inter-rater reliability for anterolateral ligament thickness was poor, ICC = 0.35 (95% CI: –0.06–0.63). The inter-rater reliability for anterolateral ligament length and width was good, ICC = 0.80 (95% CI 0.64–0.89), ICC = 0.88 (95% CI 0.79–0.94), respectively; and the inter-rater reliability for the distance between insertion and lateral tibia plateau was excellent, ICC = 0.96 (95% CI 0.93–0.98). Conclusions: Ultrasonography is a reliable method for evaluating the anterolateral ligament. There is an excellent reliability for the distal part of the anterolateral ligament. As injuries usually occur in this part of the ligament, this protocol may be used to evaluate the anterolateral ligament in patients with suspected anterior cruciate ligament tears in clinical practice.
Purpose. Ultrasound tissue characterization (UTC) is used to visualize and quantify the Achilles tendon structure. We investigated the intra-rater and inter-rater reliability of UTC for quantifying the midportion tendon structure and the area of maximum degeneration (AoMD) in military personnel with midportion Achilles tendinopathy. Method. UTC scans of 50 patients (16–60 years) were processed twice by rater 1 and once by rater 2. First, the midportion tendon structure was quantified and subsequently the AoMD. The intraclass correlation coefficient (ICC) was calculated for echo-types I, II, III, IV, aligned fibrillar structure (echo-types I + II), and disorganized tendon structure (echo-types III + IV). Results. For midportion tendon structure, all ICC values were excellent for intra-rater reliability (range: 0.97 to 0.99) and inter-rater reliability (range: 0.98 to 0.99). Regarding the AoMD, intra-rater reliability showed excellent ICC values for all echo-types (range: 0.94 to 0.98) except for echo-type II (0.85). Inter-rater reliability showed excellent ICC values for all echo-types (range: 0.92 to 0.98). Conclusion. Processing of UTC scans is highly reliable in quantifying the midportion Achilles tendon structure and the AoMD.
Background Extracorporeal shockwave therapy (ESWT) is used commonly to treat pain and function in Achilles tendinopathy (AT). The aim of this study was to synthesize the evidence from (non-) randomized controlled trials, to determine the clinical effectiveness of ESWT for mid-portion Achilles tendinopathy (mid-AT) and insertional Achilles tendinopathy (ins-AT) separately. Methods We searched PubMed/Medline, Embase (Ovid), and Cochrane Central, up to January 2021. Unpublished studies and gray literature were searched in trial registers (ACTRN, ChiCTR, ChiCtr, CTRI, DRKS, EUCTR, IRCT, ISRCTN, JPRN UMIN, ClinicalTrials.gov, NTR, TCTR) and databases (OpenGrey.eu, NARCIS.nl, DART-Europe.org, OATD.org). Randomized controlled trials (RCTs) and non-randomized controlled clinical trials (CCTs) were eligible when investigating the clinical effectiveness of ESWT for chronic mid-AT or chronic ins-AT. We excluded studies that focused on treating individuals with systemic conditions, and studies investigating mixed cohorts of mid-AT and ins-AT, when it was not possible to perform a subgroup analysis for both clinical entities separately. Two reviewers independently performed the study selection, quality assessment, data extraction, and grading of the evidence levels. Discrepancies were resolved through discussion or by consulting a third reviewer when necessary. Results We included three RCTs on mid-AT and four RCTs on ins-AT. For mid-AT, moderate quality of evidence was found for the overall effectiveness of ESWT compared to standard care, with a pooled mean difference (MD) on the VISA-A of 9.08 points (95% CI 6.35–11.81). Subgroup analysis on the effects of ESWT additional to standard care for mid-AT resulted in a pooled MD on the VISA-A of 10.28 points (95% CI 7.43–13.12). For ins-AT, we found very low quality of evidence, indicating that, overall, ESWT has no additional value over standard care, with a standardized mean difference (SMD) of − 0.02 (95% CI − 0.27 to 0.23). Subgroup analysis to determine the effect of ESWT additional to standard care for ins-AT showed a negative effect (SMD − 0.29; 95% CI − 0.56 to − 0.01) compared to standard care alone. Conclusions There is moderate evidence supporting the effectiveness of ESWT additional to a tendon loading program in mid-AT. Evidence supporting the effectiveness of ESWT for ins-AT is lacking. Trial Registration: PROSPERO Database; No. CRD42021236107.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.