To ensure effective aeration of the biological wastewater treatment process, easy-to-operate and not too energy-intensive units are needed. Jet aerators have such capabilities. In this study, the authors searched for the best hole shape for the aeration nozzles. It was determined that a nozzle with an elongated hole has the largest size of the actively aerated zone. Experimental studies of nozzles of a diameter of 56 mm with nozzles of elongated shape showed that the best characteristics of mass transfer are provided by nozzles with a total area of holes of 356 mm2 at a flow rate of 10 … 12 m/s. For practical calculations, an equation was obtained for the dependence of the oxygen transfer coefficient KLa(20) on the complex criterion vn, and a method for calculating aeration units was developed, which is applicable for aerators with elongated holes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.