A new, consistent and objective methodology, using a CCD camra to map flame luminosity, was applied for measuring wall b e heights. Experiments in six distinct wall configurations were conducted by simulating a wall fire via gaseous burners. The wall width was fixed at 0.4m and the burner height was set at 0. 2 5~ at 0. 5~ or at lm In a first time, the wall, 2m high, was confined by water cooled (65" C) sidewalls a) over its total height so that the flames were entraining air &om the fiond only or b) over its lower part beyond which f h~s were uncon6ned and could also entrain air sidewise. Then, the wall was unconfined over its total helght (2.5m high) and the air was entrained &om the front and at the side. Three hels were tested : methane, propane and acetylene. The present consistent and objective wall flame height measurements were essential for the development of new wall h e height correlations that include effects of burner (pyrolysis) height, wall width and confinement by sidewalls.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.