A validated high-performance liquid chromatography-diode array detector method for simultaneous determination of the acaricide fenpyroximate on grape was developed. Estimated limit of detection and limit of quantification for fenpyroximate were 0.01 and 0.05 mg kg À1 , respectively. The intra-and inter-day precisions performed with relative standard deviation were better than 9.3% and 8%, respectively, while recoveries were in the range of 88.5%-100.4%. Residue levels of fenpyroximate in grape samples collected 10 days after field application were below the established maximum residue level values. The dissipation rates of fenpyroximate were described using first-order kinetics and its half-life, were approximately 3.5 days in grape. This study provides basic information for developing regulations to safeguard the use of fenpyroximate in grapes and prevent any potential health concerns for consumers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.