Italy) (4) Interdisciplinary Centre for Nanostructured Materials and Interfaces (CIMaINa), Milano (Italy) (5) Fondazione IRCCS "Istituto Nazionale dei Tumori", Milano (Italy)
The purpose of this work is to investigate the capability of the FLUKA Monte Carlo (MC) code to simulate the Elekta Leksell Gamma Knife Perfexion (LGK-PFX) and reproduce the Treatment Planning System (TPS) Leksell GammaPlan version 8.2 (LGP) dose calculations for the case of a water equivalent phantom target. Thanks to the collaboration with Elekta Instruments AB, the collimation system geometry, the source positions and all the involved material have been simulated in detail. The relative linear dose distribution along the three coordinate axes, for each collimator size, and the Relative Output Factors (ROF) have been investigated. The simulation has been validated comparing simulated linear dose profiles with measurements performed with EBT radiochromic films. The acceptance criterion between experimental data and FLUKA results is based on the gamma index (GI) method. The FLUKA MC calculation for the ROF provided the values of 0.920 for the 8 mm collimators and 0.800 for the 4 mm collimators. These values are in good agreement with the Elekta reference data of 0.924 and 0.805 respectively. The percentage difference between calculated and reference values for the ROF is under 1% and within the FLUKA uncertainty. Also the simulated relative dose profiles show a good agreement with the LGP calculation expressed by means of the gamma index method. This established accuracy proves that FLUKA is a suitable and powerful tool in order to reproduce successfully the LGP calculations for the homogeneous media.
Kilovoltage CBCT is effective in evaluating set-up accuracy in H&N patients. CTV-PTV margins of 5 mm are safe and are currently adopted at our centre; however, some special situations, such as re-irradiation or the close proximity of organs at risk and high-dose regions, could benefit from daily image registration and lower (i.e., 3 mm) margins.
The use of synthetic gel matrices prepared with poly(vinyl-alcohol) (PVA) cross-linked by glutaraldehyde (GTA) contributed to enhance the interest toward radiochromic Fricke gel (FG) dosimeters. As it occurs in several chemical dosimeters, the response of PVA-GTA Fricke gels could be affected by temperature. Aim of this work is to study the dependence of the dosimetric properties of PVA-GTA Fricke gel dosimeters both on the irradiation temperature and on temperature changes possibly occurring between the irradiation and readout phases. Such effects were investigated by means of magnetic resonance imaging (MRI) and optical absorbance (OA) measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.