An experimentally validated simple standardized method for making precise measurements of the spinal canal directly from the video display of a CT scanner is described. Using this method, normal values for anteroposterior diameter, interpediculate distance, and cross-sectional area of the lumbar spinal canal have been determined in a series of 60 adults. A careful study of canal configuration combined with the prudent use of the normal values should allow the CT diagnosis of lumbar spinal stenosis to be made with a high level of confidence.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.